Diagnostic performance of axillary-vein distensibility index (AXV-DI) versus inferior-vena-cava distensibility index (IVC-DI) for predicting fluid responsiveness in patients with septic shock

Background Septic shock relies on early goal-directed fluid resuscitation. Inferior vena cava (IVC) ultrasound is standard for volume evaluation, yet the IVC is frequently affected by abdominal distension, emphysema or high intra-abdominal pressure. This study aimed to compare the diagnostic performance of axillary vein distensibility index (AXV-DI) and inferior vena cava distensibility index (IVC-DI) for assessing fluid responsiveness in mechanically ventilated patients with septic shock in the intensive care unit. Materials and methods This was a single-center prospective observational study that enrolled 95 mechanically ventilated patients with septic shock in the ICU. A standardized fluid challenge with 500 mL of Lactated Ringer's solution infused intravenously over 15 min was performed. The primary outcome was the comparison of the diagnostic performance (area under the receiver operating characteristic curve) of AXV-DI vs. IVC-DI for predicting fluid responsiveness. The secondary outcome was the changes in hemodynamic and ultrasonic parameters before and after standardized fluid challenge in responder and non-responder groups. Results Eighty-six patients were analyzed (60 responders, 26 non-responders). For the primary outcome, the ROC AUC values for predicting fluid responsiveness were 0.93 for IVC-DI and 0.80 for AXV-DI. The DeLong test confirmed that IVC-DI exhibited significantly superior diagnostic performance compared with AXV-DI ( P = 0.009). For the secondary outcome, responders presented more significant changes in LVOT-VTI and venous distensibility indices after fluid resuscitation compared with non-responders. Baseline hemodynamic and ultrasonic parameters were significantly different between the two groups. Conclusions Both AXV-DI and IVC-DI can predict fluid responsiveness in patients with septic shock, although AXV-DI exhibits lower diagnostic performance than IVC-DI.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-10-28
DOI
https://doi.org/10.3389/fmed.2026.1926984
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic performance of axillary-vein distensibility index (AXV-DI) versus inferior-vena-cava distensibility index (IVC-DI) for predicting fluid responsiveness in patients with septic shock

Peng Shen, Fei Guo, Xiaoyun Zou, Xianzhou Quan et al.
1 links
Frontiers in Medicine
Sepsis Diagnosis and Treatment
article

Diagnostic performance of axillary-vein distensibility index (AXV-DI) versus inferior-vena-cava distensibility index (IVC-DI) for predicting fluid responsiveness in patients with septic shock

Peng Shen, Fei Guo, Xiaoyun Zou, Xianzhou Quan, Jianguo Zhang, Haien Yu
article en

Abstract

Background Septic shock relies on early goal-directed fluid resuscitation. Inferior vena cava (IVC) ultrasound is standard for volume evaluation, yet the IVC is frequently affected by abdominal distension, emphysema or high intra-abdominal pressure. This study aimed to compare the diagnostic performance of axillary vein distensibility index (AXV-DI) and inferior vena cava distensibility index (IVC-DI) for assessing fluid responsiveness in mechanically ventilated patients with septic shock in the intensive care unit. Materials and methods This was a single-center prospective observational study that enrolled 95 mechanically ventilated patients with septic shock in the ICU. A standardized fluid challenge with 500 mL of Lactated Ringer's solution infused intravenously over 15 min was performed. The primary outcome was the comparison of the diagnostic performance (area under the receiver operating characteristic curve) of AXV-DI vs. IVC-DI for predicting fluid responsiveness. The secondary outcome was the changes in hemodynamic and ultrasonic parameters before and after standardized fluid challenge in responder and non-responder groups. Results Eighty-six patients were analyzed (60 responders, 26 non-responders). For the primary outcome, the ROC AUC values for predicting fluid responsiveness were 0.93 for IVC-DI and 0.80 for AXV-DI. The DeLong test confirmed that IVC-DI exhibited significantly superior diagnostic performance compared with AXV-DI ( P = 0.009). For the secondary outcome, responders presented more significant changes in LVOT-VTI and venous distensibility indices after fluid resuscitation compared with non-responders. Baseline hemodynamic and ultrasonic parameters were significantly different between the two groups. Conclusions Both AXV-DI and IVC-DI can predict fluid responsiveness in patients with septic shock, although AXV-DI exhibits lower diagnostic performance than IVC-DI.

Frontiers in MedicineVol. 13
Qingdao University (CN), Peking University People's Hospital (CN), Qingdao Women and Children's Hospital (CN)
Peking University People's Hospital
Good health and well-being
Openalex Percentile: Top 12%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon