Hardware-Tripped Phase Imbalance and Neutral Fault Detection System for Low-Voltage Distribution Grids

In Bangladesh’s low-voltage distribution network, power lines often get severely unbalanced. This happens because of heavy single-phase commercial loads, unequal consumer allocation across phases (A, B, C), and widespread illegal tapping. When one phase carries significantly more load than the others, a heavy return current flows through the neutral wire (IN ). This causes neutral line overheating, voltage fluctuations that damage home electronics, and frequent transformer coil burnouts. Traditional digital protection relays use a single microcontroller to run sampling loops (ADCs) and execute trip logic in software. But running code takes time—introducing 15 ms to 50 ms of processing delay. During a massive current surge, that delay is long enough to destroy transformer coils or freeze the processor entirely.This project solves the problem by splitting the job into two independent layers:• Layer 1 (DLD Hardware Protection): Pure logic gate ICs and comparators continuously monitor currents and cut off power in under 2 ms during a fault.• Layer 2 (ESP32 Edge Telemetry): The ESP32 handles secondary tasks—calculating imbalance percentages (PUF%), logging fault timestamps, and sending real time updates to a web dashboard

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-28
DOI
https://doi.org/10.5281/zenodo.23743216
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hardware-Tripped Phase Imbalance and Neutral Fault Detection System for Low-Voltage Distribution Grids

Rahim Md. Shahriyar
Zenodo (CERN European Organization for Nuclear Research)
Power Systems Fault Detection
article

Hardware-Tripped Phase Imbalance and Neutral Fault Detection System for Low-Voltage Distribution Grids

Rahim Md. Shahriyar
article en

Abstract

In Bangladesh’s low-voltage distribution network, power lines often get severely unbalanced. This happens because of heavy single-phase commercial loads, unequal consumer allocation across phases (A, B, C), and widespread illegal tapping. When one phase carries significantly more load than the others, a heavy return current flows through the neutral wire (IN ). This causes neutral line overheating, voltage fluctuations that damage home electronics, and frequent transformer coil burnouts. Traditional digital protection relays use a single microcontroller to run sampling loops (ADCs) and execute trip logic in software. But running code takes time—introducing 15 ms to 50 ms of processing delay. During a massive current surge, that delay is long enough to destroy transformer coils or freeze the processor entirely.This project solves the problem by splitting the job into two independent layers:• Layer 1 (DLD Hardware Protection): Pure logic gate ICs and comparators continuously monitor currents and cut off power in under 2 ms during a fault.• Layer 2 (ESP32 Edge Telemetry): The ESP32 handles secondary tasks—calculating imbalance percentages (PUF%), logging fault timestamps, and sending real time updates to a web dashboard

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon