Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair

Background: Fluorescence-guided (FG) surgery using near-infrared imaging has been adopted to enhance intraoperative visualization in multiple surgical fields. In foregut surgery, calibration tubes are routinely used to calibrate crural closure but due to limited visibility carry a risk of iatrogenic injury, including esophageal or gastric perforation. Techniques that improve visualization of these devices may support safer intraoperative management. Case Presentation: A 75-year-old woman with a symptomatic paraesophageal hiatal hernia and partial gastric volvulus underwent robotic paraesophageal hiatal hernia repair with Toupet fundoplication. A FG gastric calibration tube (size 40 Fr, Endolumik Inc.), was inserted under near-infrared visualization and advanced down the esophagus and into the stomach. The device was used to (1) evacuate gastric contents, (2) guide tube positioning past the gastroesophageal junction, (3) inform mediastinal dissection/esophageal mobilization, (4) enable FG measuring of the length of esophageal mobilization below the diaphragm, and (5) calibrate both crural closure and fundoplication. The procedure was completed without intraoperative complications. The patient was discharged on postoperative day 1 and reported resolution of dysphagia at 8-week follow-up. Discussion: This case demonstrates the feasibility of FG calibration during robotic paraesophageal hernia repair. Continuous visualization of the calibration device provided an additional intraoperative reference during dissection in the setting of distorted anatomy. This approach may offer improved orientation compared with conventional calibration techniques, although its effect on clinical outcomes remains unknown.

Authors

Institutions

Publication Details

Journal
CRSLS Journal of the Society of Laparoscopic and Robotic Surgeons
Published
2026-10-27
DOI
https://doi.org/10.4293/crsls.2026.00069
Primary Topic
Gastroesophageal reflux and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair

Mustafa Hajjar, Hayley Harman, Nova L. Szoka, Edgardo Reyes et al.
CRSLS Journal of the Society of Laparoscopic and Robotic Surgeons
Gastroesophageal reflux and treatments
article

Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair

Mustafa Hajjar, Hayley Harman, Nova L. Szoka, Edgardo Reyes, Andres Fontaine-Nicola
article en

Abstract

Background: Fluorescence-guided (FG) surgery using near-infrared imaging has been adopted to enhance intraoperative visualization in multiple surgical fields. In foregut surgery, calibration tubes are routinely used to calibrate crural closure but due to limited visibility carry a risk of iatrogenic injury, including esophageal or gastric perforation. Techniques that improve visualization of these devices may support safer intraoperative management. Case Presentation: A 75-year-old woman with a symptomatic paraesophageal hiatal hernia and partial gastric volvulus underwent robotic paraesophageal hiatal hernia repair with Toupet fundoplication. A FG gastric calibration tube (size 40 Fr, Endolumik Inc.), was inserted under near-infrared visualization and advanced down the esophagus and into the stomach. The device was used to (1) evacuate gastric contents, (2) guide tube positioning past the gastroesophageal junction, (3) inform mediastinal dissection/esophageal mobilization, (4) enable FG measuring of the length of esophageal mobilization below the diaphragm, and (5) calibrate both crural closure and fundoplication. The procedure was completed without intraoperative complications. The patient was discharged on postoperative day 1 and reported resolution of dysphagia at 8-week follow-up. Discussion: This case demonstrates the feasibility of FG calibration during robotic paraesophageal hernia repair. Continuous visualization of the calibration device provided an additional intraoperative reference during dissection in the setting of distorted anatomy. This approach may offer improved orientation compared with conventional calibration techniques, although its effect on clinical outcomes remains unknown.

CRSLS Journal of the Society of Laparoscopic and Robotic SurgeonsVol. 13(4)
West Virginia University (US), North Shore University Hospital (US), University of California San Diego (US)
Openalex Percentile: Top 9%
Gastroesophageal reflux and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon