Transit-time flow measurement and high-frequency ultrasound for renal allograft vascular assessment

Background: To describe arterial and venous flow and pulsatility index in renal allografts measured by transit-time flow measurement, anastomotic morphology assessed by intraoperative high-frequency ultrasound, and early outcomes after kidney transplantation. Methods: This retrospective–prospective descriptive case series included 92 kidney transplant recipients at Military Hospital 175 from December 2024 to August 2026. Following reperfusion, arterial and venous flow and pulsatility index were measured using transit-time flow measurement; high-frequency ultrasound was used to select the anastomotic site and assess vascular morphology and patency. Early outcomes included intraoperative urine output, serum creatinine, estimated glomerular filtration rate, delayed graft function, and vascular reoperation. Results: Mean age was 41.9 ± 9.8 years, and 66.3% were male. Multiple graft arteries occurred in 31.5% and two graft veins in 5.4%. Median arterial and venous flows were 558.5 mL/min (interquartile range, 446.2–712.8) and 426.0 mL/min (303.0–596.2), respectively; pulsatility indices were 1.00 (0.80–1.10) and 0.70 (0.50–1.00). No anastomotic stenosis, occlusion, or revision occurred. All grafts produced immediate urine. Median creatinine decreased from 629.7 to 99.7 µmol/L, while estimated glomerular filtration rate increased from 7.8 to 72.5 mL/min/1.73 m² by day 7 (p < 0.001). Arterial flow correlated positively with day-7 estimated glomerular filtration rate (ρ = 0.331; p = 0.001), whereas venous pulsatility index correlated negatively (ρ = −0.212; p = 0.042). No delayed graft function or vascular reoperation occurred. Conclusion: Transit-time flow measurement and high-frequency ultrasound provided complementary intraoperative hemodynamic and morphological information. The absence of a control group and clinical events precludes causal inference or predictive threshold establishment.

Authors

Publication Details

Journal
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Published
2026-10-28
DOI
https://doi.org/10.47972/vjcts.v57i.1895
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transit-time flow measurement and high-frequency ultrasound for renal allograft vascular assessment

Trường Vũ Nguyễn, Đình Cẩm Trương, Thao Cuong Lam, Thi Thuy Ha Phung et al.
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Renal Transplantation Outcomes and Treatments
article

Transit-time flow measurement and high-frequency ultrasound for renal allograft vascular assessment

Trường Vũ Nguyễn, Đình Cẩm Trương, Thao Cuong Lam, Thi Thuy Ha Phung, Ngoc Tuan Nguyen
article en

Abstract

Background: To describe arterial and venous flow and pulsatility index in renal allografts measured by transit-time flow measurement, anastomotic morphology assessed by intraoperative high-frequency ultrasound, and early outcomes after kidney transplantation. Methods: This retrospective–prospective descriptive case series included 92 kidney transplant recipients at Military Hospital 175 from December 2024 to August 2026. Following reperfusion, arterial and venous flow and pulsatility index were measured using transit-time flow measurement; high-frequency ultrasound was used to select the anastomotic site and assess vascular morphology and patency. Early outcomes included intraoperative urine output, serum creatinine, estimated glomerular filtration rate, delayed graft function, and vascular reoperation. Results: Mean age was 41.9 ± 9.8 years, and 66.3% were male. Multiple graft arteries occurred in 31.5% and two graft veins in 5.4%. Median arterial and venous flows were 558.5 mL/min (interquartile range, 446.2–712.8) and 426.0 mL/min (303.0–596.2), respectively; pulsatility indices were 1.00 (0.80–1.10) and 0.70 (0.50–1.00). No anastomotic stenosis, occlusion, or revision occurred. All grafts produced immediate urine. Median creatinine decreased from 629.7 to 99.7 µmol/L, while estimated glomerular filtration rate increased from 7.8 to 72.5 mL/min/1.73 m² by day 7 (p < 0.001). Arterial flow correlated positively with day-7 estimated glomerular filtration rate (ρ = 0.331; p = 0.001), whereas venous pulsatility index correlated negatively (ρ = −0.212; p = 0.042). No delayed graft function or vascular reoperation occurred. Conclusion: Transit-time flow measurement and high-frequency ultrasound provided complementary intraoperative hemodynamic and morphological information. The absence of a control group and clinical events precludes causal inference or predictive threshold establishment.

Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt NamVol. 57
Good health and well-being
Openalex Percentile: Top 9%
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Transit-time flow measurement and high-frequency ultrasound for renal allograft vascular assessment — Trường Vũ Nguyễn, Đình Cẩm Trương, et al. · Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam (2026) | TGRS Research Map | TGRS