Resilient Precast Concrete Structures Using FRP Bolts and Tendons: Experimental Validation and a Resilience Performance Index

Abstract Fiber-reinforced polymer (FRP) reinforcement is linear-elastic to rupture and is therefore brittle at the material level. However, this does not necessarily imply brittle response at the structural level when deformation, energy dissipation, and recovery are intentionally designed. Recent experimental and analytical evidence showed that precast concrete structures with FRP systems could achieve functional ductility and recoverability when ductile-by-design mechanisms were adopted, rather than relying on reinforcement yielding. For precast segmental beams prestressed with unbonded FRP tendons, functional ductility has been achieved through controlled joint opening/rocking, strain redistribution along unbonded tendons, and localized inelastic deformation and damage at interfaces. For precast beam–column joints assembled using FRP bolts and dry or hybrid interfaces, stable cyclic and impact responses have been reported when damage is shifted to intended interface mechanisms and confined to repairable regions, while the FRP fasteners remain elastic. To quantify the resilience of structures, a resilience performance index (RPI) is proposed based on the SDuMuRS concept (Sustainability, Durability, Multihazard resistance, Recovery, and Smart monitoring and management). The RPI is intended for structure-level application and implemented using conditional scoring when only partial pillar data are available from component-level studies. A worked example is provided for precast FRP-reinforced joints under impact loading, showing that fiber-reinforced concrete can improve conditional RPI values by simultaneously reducing peak deformation and enhancing recentering capacity. This paper proposes a mechanics-based and conditional resilience assessment framework for precast FRP systems, linking joint opening, tendon/bolt elasticity, residual deformation, recoverability, durability constraints, and smart monitoring into a unified RPI structure.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-10-28
DOI
https://doi.org/10.1061/jccof2.cceng-5675
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilient Precast Concrete Structures Using FRP Bolts and Tendons: Experimental Validation and a Resilience Performance Index

Thong Minh Pham
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
article

Resilient Precast Concrete Structures Using FRP Bolts and Tendons: Experimental Validation and a Resilience Performance Index

Thong Minh Pham
article en

Abstract

Abstract Fiber-reinforced polymer (FRP) reinforcement is linear-elastic to rupture and is therefore brittle at the material level. However, this does not necessarily imply brittle response at the structural level when deformation, energy dissipation, and recovery are intentionally designed. Recent experimental and analytical evidence showed that precast concrete structures with FRP systems could achieve functional ductility and recoverability when ductile-by-design mechanisms were adopted, rather than relying on reinforcement yielding. For precast segmental beams prestressed with unbonded FRP tendons, functional ductility has been achieved through controlled joint opening/rocking, strain redistribution along unbonded tendons, and localized inelastic deformation and damage at interfaces. For precast beam–column joints assembled using FRP bolts and dry or hybrid interfaces, stable cyclic and impact responses have been reported when damage is shifted to intended interface mechanisms and confined to repairable regions, while the FRP fasteners remain elastic. To quantify the resilience of structures, a resilience performance index (RPI) is proposed based on the SDuMuRS concept (Sustainability, Durability, Multihazard resistance, Recovery, and Smart monitoring and management). The RPI is intended for structure-level application and implemented using conditional scoring when only partial pillar data are available from component-level studies. A worked example is provided for precast FRP-reinforced joints under impact loading, showing that fiber-reinforced concrete can improve conditional RPI values by simultaneously reducing peak deformation and enhancing recentering capacity. This paper proposes a mechanics-based and conditional resilience assessment framework for precast FRP systems, linking joint opening, tendon/bolt elasticity, residual deformation, recoverability, durability constraints, and smart monitoring into a unified RPI structure.

Journal of Composites for ConstructionVol. 31(1)
Adelaide University (AU), The University of Adelaide (AU)
Industry, innovation and infrastructure
Openalex Percentile: Top 16%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon