Concentration-Dependent Human Serum Albumin Layers on Ti-6Al-4V Modulate Mammalian Cells and S. aureus Responses

Orthopaedic Ti-6Al-4V implants face two persistent risks: early infection and limited osseointegration. Human serum albumin (HSA) coatings may influence interactions between titanium interfaces in both mammalian and bacterial cells, but these effects may depend on the concentration used during coating preparation. In this study, Ti-6Al-4V discs were PEI-functionalized and coated with HSA solutions ranging from 200 to 500 µg·mL−1. Surface properties were assessed by AFM, contact-angle goniometry, and XPS, while apparent surface-associated HSA and short-term coating retention were estimated using a BCA depletion approach. The apparent surface-associated HSA, estimated from solution depletion, increased with increasing coating concentration, and all coated samples remained ultrasmooth (Ra < 1 nm), providing a comparable physical baseline. In FBS-free DMEM, at least 70% of the initially estimated HSA remained after 3 days. SaOS-2 metabolic activity was reduced at coating concentrations of 200–300 µg·mL−1, whereas at concentrations of 400–500 µg·mL−1 the values did not differ from polished Ti-6Al-4V after 72 h. LDH release remained unchanged across groups. No significant changes were observed in the expression of osteogenic markers and miRNAs analysed among the HSA-coated samples. Macrophage-like cell (THP-1) attachment was reduced on HSA-coated surfaces, while inflammatory gene expression remained largely unchanged. S. aureus adhesion was quantified by CFU counting after 3 h and 24 h, and SEM analysis after 3 h. When culturing S. aureus on 500 µg·mL−1 coated discs, an approximately 1-log10 reduction in recoverable S. aureus CFU vs polished Ti-6Al-4V was observed. Overall, these findings demonstrate a concentration-dependent response to HSA-modified Ti-6Al-4V, with favourable short-term cytocompatibility at higher coating concentrations and reduced S. aureus adhesion at the highest concentration tested.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-10-28
DOI
https://doi.org/10.3390/jfb17110549
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concentration-Dependent Human Serum Albumin Layers on Ti-6Al-4V Modulate Mammalian Cells and S. aureus Responses

Zhongqian Xi, Christof Neumann, Jan Trautmann, Britt Wildemann et al.
2 links
Journal of Functional Biomaterials
Bone Tissue Engineering Materials
article

Concentration-Dependent Human Serum Albumin Layers on Ti-6Al-4V Modulate Mammalian Cells and S. aureus Responses

Zhongqian Xi, Christof Neumann, Jan Trautmann, Britt Wildemann, Andrey Turchanin, Klaus D. Jandt, Oliwia Makarewicz, Mandana Azari
article en

Abstract

Orthopaedic Ti-6Al-4V implants face two persistent risks: early infection and limited osseointegration. Human serum albumin (HSA) coatings may influence interactions between titanium interfaces in both mammalian and bacterial cells, but these effects may depend on the concentration used during coating preparation. In this study, Ti-6Al-4V discs were PEI-functionalized and coated with HSA solutions ranging from 200 to 500 µg·mL−1. Surface properties were assessed by AFM, contact-angle goniometry, and XPS, while apparent surface-associated HSA and short-term coating retention were estimated using a BCA depletion approach. The apparent surface-associated HSA, estimated from solution depletion, increased with increasing coating concentration, and all coated samples remained ultrasmooth (Ra < 1 nm), providing a comparable physical baseline. In FBS-free DMEM, at least 70% of the initially estimated HSA remained after 3 days. SaOS-2 metabolic activity was reduced at coating concentrations of 200–300 µg·mL−1, whereas at concentrations of 400–500 µg·mL−1 the values did not differ from polished Ti-6Al-4V after 72 h. LDH release remained unchanged across groups. No significant changes were observed in the expression of osteogenic markers and miRNAs analysed among the HSA-coated samples. Macrophage-like cell (THP-1) attachment was reduced on HSA-coated surfaces, while inflammatory gene expression remained largely unchanged. S. aureus adhesion was quantified by CFU counting after 3 h and 24 h, and SEM analysis after 3 h. When culturing S. aureus on 500 µg·mL−1 coated discs, an approximately 1-log10 reduction in recoverable S. aureus CFU vs polished Ti-6Al-4V was observed. Overall, these findings demonstrate a concentration-dependent response to HSA-modified Ti-6Al-4V, with favourable short-term cytocompatibility at higher coating concentrations and reduced S. aureus adhesion at the highest concentration tested.

Journal of Functional BiomaterialsVol. 17(11)
Leibniz Institute of Photonic Technology (DE), Jena University Hospital (DE), Center for Sepsis Control and Care (DE), Friedrich Schiller University Jena (DE)
Deutsche Forschungsgemeinschaft
Good health and well-being
Openalex Percentile: Top 25%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon