Post-earthquake fire (PEF) is a critical multi-hazard scenario that can cause severe structural degradation and collapse, even in buildings designed for modern seismic and fire codes. This study conducts a comprehensive numerical investigation of a reinforced concrete columns behaviour under seismic lateral loading and post-earthquake fire loading. We developed a validated 3D finite element (FE) model in ANSYS Mechanical to simulate coupled thermal–mechanical behaviour, incorporating nonlinear concrete damage, reinforcement yielding, and heat-dependent material properties. Experimental results reported in the literature were used for validation analyses using FEA tools such as ANSYS, and a comprehensive parametric study was subsequently carried out to examine the influence of axial load ratio (0.1–0.4), concrete cover thickness (25–50 mm), and number of fire-exposed faces (one, three, four) on PEF resistance. Results show that higher axial load ratios significantly reduce ductility and fire resistance, while more fireexposed surfaces accelerate reinforcement heating and stiffness degradation. Thicker concrete cover improves thermal protection but can reduce lateral resistance by reducing effective depth. Finite element validation results showed good agreement with experimental residual lateral load capacity, with margins of error of 4.7 parcent and 2.2 parcent for lateral load capacity and ductility ratio, respectively. Concrete cover size influenced insulation efficiency and residual strength. Compared with 35, 40, and 50mm concrete cover, a nominal 25mm concrete cover showed a 3.2 parcent, 19.1 parcent, and 59.63 parcent increase in rebar reinforcement temperature. Postearthquake fire (PEF) peak lateral load capacity and fire resistance also decreased by 8.1 parcent compared with seismic lateral loading alone. The findings highlight critical design-sensitive parameters governing PEF resistance and emphasise the need for integrated multi-hazard design approaches in structural engineering practice.

Authors

Institutions

Publication Details

Journal
International Journal of Inventive Engineering and Sciences
Published
2026-10-28
DOI
https://doi.org/10.35940/ijies.d8398.15041126
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation of Post-Earthquake Fire Resistance of Reinforced Concrete Column

Girmay Mengesha Azanaw, Selamawit Jember Tsegaye
2 links
International Journal of Inventive Engineering and Sciences
Fire effects on concrete materials
article

Numerical Investigation of Post-Earthquake Fire Resistance of Reinforced Concrete Column

Girmay Mengesha Azanaw, Selamawit Jember Tsegaye
article en

Abstract

Post-earthquake fire (PEF) is a critical multi-hazard scenario that can cause severe structural degradation and collapse, even in buildings designed for modern seismic and fire codes. This study conducts a comprehensive numerical investigation of a reinforced concrete columns behaviour under seismic lateral loading and post-earthquake fire loading. We developed a validated 3D finite element (FE) model in ANSYS Mechanical to simulate coupled thermal–mechanical behaviour, incorporating nonlinear concrete damage, reinforcement yielding, and heat-dependent material properties. Experimental results reported in the literature were used for validation analyses using FEA tools such as ANSYS, and a comprehensive parametric study was subsequently carried out to examine the influence of axial load ratio (0.1–0.4), concrete cover thickness (25–50 mm), and number of fire-exposed faces (one, three, four) on PEF resistance. Results show that higher axial load ratios significantly reduce ductility and fire resistance, while more fireexposed surfaces accelerate reinforcement heating and stiffness degradation. Thicker concrete cover improves thermal protection but can reduce lateral resistance by reducing effective depth. Finite element validation results showed good agreement with experimental residual lateral load capacity, with margins of error of 4.7 parcent and 2.2 parcent for lateral load capacity and ductility ratio, respectively. Concrete cover size influenced insulation efficiency and residual strength. Compared with 35, 40, and 50mm concrete cover, a nominal 25mm concrete cover showed a 3.2 parcent, 19.1 parcent, and 59.63 parcent increase in rebar reinforcement temperature. Postearthquake fire (PEF) peak lateral load capacity and fire resistance also decreased by 8.1 parcent compared with seismic lateral loading alone. The findings highlight critical design-sensitive parameters governing PEF resistance and emphasise the need for integrated multi-hazard design approaches in structural engineering practice.

International Journal of Inventive Engineering and SciencesVol. 13(10)
University of Gondar (ET)
Sustainable cities and communities, Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon