A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes

AIMS: The continuous glucose monitoring (CGM)-derived glucose management indicator (GMI) is used for estimating glycated haemoglobin (HbA1c). This study assessed agreement between GMI-calculated using both original and updated (uGMI) models-and laboratory-measured HbA1c across Dexcom, MiniMed and Abbott sensors. MATERIALS AND METHODS: Real-world data from adults with type 1 diabetes using automated insulin delivery were retrospectively analysed. Δ(GMI-HbA1c) and Δ(uGMI-HbA1c) were evaluated over 90 days preceding HbA1c (n = 383) and over 28 days preceding HbA1c (n = 375). Agreement was measured as directional difference, indicating GMI overestimation or underestimation of HbA1c, and absolute difference, indicating magnitude of agreement between GMI and HbA1c. Agreement was assessed across sensor groups using ANCOVA, adjusting for coefficient of variation and ethnicity. RESULTS: Although mean directional differences were statistically significant for Δ(GMI-HbA1c) and Δ(uGMI-HbA1c) across all sensor groups (p < 0.001), differences were small and not clinically important, 90-day adjusted means (95% CI)-Δ(GMI-HbA1c): Dexcom 0.17% (0.09, 0.25), MiniMed -0.15% (-0.28, -0.02), Abbott -0.08% (-0.25, 0.09); Δ(uGMI-HbA1c): Dexcom 0.22% (0.14, 0.30), MiniMed -0.10% (-0.23, 0.02), Abbott -0.02% (-0.19, 0.15). Mean absolute difference did not significantly differ across sensor groups-Δ(GMI-HbA1c): 0.42%-0.51% (p = 0.353), Δ(uGMI-HbA1c): 0.41%-0.52% (p = 0.221). CONCLUSIONS: GMI/uGMI performed consistently across sensor groups. Where clinically meaningful discrepancies between GMI/uGMI and HbA1c arise, these warrant interpretation within the context of individual clinical and laboratory factors rather than attribution to sensor manufacturer, reinforcing the need for personalised use of GMI alongside HbA1c.

Authors

Institutions

Publication Details

Journal
Diabetes Obesity and Metabolism
Published
2026-10-27
DOI
https://doi.org/10.1111/dom.71484
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes

Monika Reddy, Viral N. Shah, Hood Thabit, Parizad Avari et al.
Diabetes Obesity and Metabolism
Diabetes Management and Research
article

A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes

Monika Reddy, Viral N. Shah, Hood Thabit, Parizad Avari, Richard M. Bergenstal, Bilal Bashir, Lavanta Farouk, Mark L. Evans, Lalantha Leelarathna, Nick S. Oliver, R Seese
article en

Abstract

AIMS: The continuous glucose monitoring (CGM)-derived glucose management indicator (GMI) is used for estimating glycated haemoglobin (HbA1c). This study assessed agreement between GMI-calculated using both original and updated (uGMI) models-and laboratory-measured HbA1c across Dexcom, MiniMed and Abbott sensors. MATERIALS AND METHODS: Real-world data from adults with type 1 diabetes using automated insulin delivery were retrospectively analysed. Δ(GMI-HbA1c) and Δ(uGMI-HbA1c) were evaluated over 90 days preceding HbA1c (n = 383) and over 28 days preceding HbA1c (n = 375). Agreement was measured as directional difference, indicating GMI overestimation or underestimation of HbA1c, and absolute difference, indicating magnitude of agreement between GMI and HbA1c. Agreement was assessed across sensor groups using ANCOVA, adjusting for coefficient of variation and ethnicity. RESULTS: Although mean directional differences were statistically significant for Δ(GMI-HbA1c) and Δ(uGMI-HbA1c) across all sensor groups (p < 0.001), differences were small and not clinically important, 90-day adjusted means (95% CI)-Δ(GMI-HbA1c): Dexcom 0.17% (0.09, 0.25), MiniMed -0.15% (-0.28, -0.02), Abbott -0.08% (-0.25, 0.09); Δ(uGMI-HbA1c): Dexcom 0.22% (0.14, 0.30), MiniMed -0.10% (-0.23, 0.02), Abbott -0.02% (-0.19, 0.15). Mean absolute difference did not significantly differ across sensor groups-Δ(GMI-HbA1c): 0.42%-0.51% (p = 0.353), Δ(uGMI-HbA1c): 0.41%-0.52% (p = 0.221). CONCLUSIONS: GMI/uGMI performed consistently across sensor groups. Where clinically meaningful discrepancies between GMI/uGMI and HbA1c arise, these warrant interpretation within the context of individual clinical and laboratory factors rather than attribution to sensor manufacturer, reinforcing the need for personalised use of GMI alongside HbA1c.

Diabetes Obesity and Metabolism
Imperial College Healthcare NHS Trust (GB), University of Cambridge (GB), Manchester Royal Infirmary (GB), Cambridge University Hospitals NHS Foundation Trust (GB), University of Manchester (GB), Manchester University NHS Foundation Trust (GB), Indiana University Indianapolis (US), Indiana University School of Medicine (US), Imperial College London (GB), HealthPartners (US)
Openalex Percentile: Top 10%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon