How many local patients does a hospital need before switching on an imported sepsis prediction model? A two-system evaluation of a silent-mode acceptance and local adaptation protocol

Objective: Hospitals, including most in the Arab region, switch on imported prediction models with a vendor threshold and a performance claim measured elsewhere. We quantified how many local patients an adopting hospital needs to detect a broken claim and to adapt the model, and the alert burden of each option. Methods: We used 40,336 intensive care unit admissions from two independent hospital systems (PhysioNet/CinC Challenge 2019; Sepsis-3 labels). A gradient-boosting early-warning model developed at one system, with a threshold for 80% sensitivity, was transported to the other, in both directions. With 100–10,000 local admissions, we evaluated silent-mode acceptance testing, threshold reset with and without labels, logistic recalibration, local retraining and vendor-informed local updating on a fixed local test set. Results: Transported unchanged, patient-level AUROC fell from 0.830 to 0.738 and from 0.834 to 0.726. The failures differed: sensitivity fell to 56.9% in one direction, while in the other alert episodes rose from 41 to 89 per 100 patient-days. Silent mode detected the sensitivity shortfall in 90% of repeats with 500 admissions and 95% with 1,000; the alert-burden rise was visible without labels at 100 admissions. A labelled threshold reset reached 80±5% sensitivity in 80–85% of repeats at 1,000 admissions and in all repeats at 2,000. Local models beat the imported model in 85–90% of repeats at 1,000 admissions and in all from 2,000, reaching AUROC 0.847 and 0.815 with fewer alerts. Conclusions: About 1,000 labelled local admissions should be a minimum before go-live, and procurement contracts should secure the right to retune and locally update the model. Author: Ahmed Abdelalim, BPharm (Al-Azhar University), VisionSeek, Incheon, South Korea. Preprint, not peer reviewed. Files: manuscript PDF, supplementary files and a code/derived-results archive. Raw data: PhysioNet/CinC Challenge 2019 (https://doi.org/10.13026/v64v-d857, CC BY 4.0), downloaded by the code and not redistributed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-28
DOI
https://doi.org/10.5281/zenodo.23722851
Primary Topic
Sepsis Diagnosis and Treatment
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

How many local patients does a hospital need before switching on an imported sepsis prediction model? A two-system evaluation of a silent-mode acceptance and local adaptation protocol

Ahmed Abdelalim
5 links
Zenodo (CERN European Organization for Nuclear Research)
Sepsis Diagnosis and Treatment
preprint

How many local patients does a hospital need before switching on an imported sepsis prediction model? A two-system evaluation of a silent-mode acceptance and local adaptation protocol

Ahmed Abdelalim
preprint en

Abstract

Objective: Hospitals, including most in the Arab region, switch on imported prediction models with a vendor threshold and a performance claim measured elsewhere. We quantified how many local patients an adopting hospital needs to detect a broken claim and to adapt the model, and the alert burden of each option. Methods: We used 40,336 intensive care unit admissions from two independent hospital systems (PhysioNet/CinC Challenge 2019; Sepsis-3 labels). A gradient-boosting early-warning model developed at one system, with a threshold for 80% sensitivity, was transported to the other, in both directions. With 100–10,000 local admissions, we evaluated silent-mode acceptance testing, threshold reset with and without labels, logistic recalibration, local retraining and vendor-informed local updating on a fixed local test set. Results: Transported unchanged, patient-level AUROC fell from 0.830 to 0.738 and from 0.834 to 0.726. The failures differed: sensitivity fell to 56.9% in one direction, while in the other alert episodes rose from 41 to 89 per 100 patient-days. Silent mode detected the sensitivity shortfall in 90% of repeats with 500 admissions and 95% with 1,000; the alert-burden rise was visible without labels at 100 admissions. A labelled threshold reset reached 80±5% sensitivity in 80–85% of repeats at 1,000 admissions and in all repeats at 2,000. Local models beat the imported model in 85–90% of repeats at 1,000 admissions and in all from 2,000, reaching AUROC 0.847 and 0.815 with fewer alerts. Conclusions: About 1,000 labelled local admissions should be a minimum before go-live, and procurement contracts should secure the right to retune and locally update the model. Author: Ahmed Abdelalim, BPharm (Al-Azhar University), VisionSeek, Incheon, South Korea. Preprint, not peer reviewed. Files: manuscript PDF, supplementary files and a code/derived-results archive. Raw data: PhysioNet/CinC Challenge 2019 (https://doi.org/10.13026/v64v-d857, CC BY 4.0), downloaded by the code and not redistributed.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
How many local patients does a hospital need before switching on an imported sepsis prediction model? A two-system evaluation of a silent-mode acceptance and local adaptation protocol — Ahmed Abdelalim · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS