Optimized dosing of spatially heterogeneous radiopharmaceutical therapy reprograms poorly immunogenic tumors to enhance response to immune checkpoint blockade

Immune checkpoint inhibitors (ICIs) are ineffective in patients with poorly immunogenic tumors due to exclusion or exhaustion of effector T cells in the tumor microenvironment (TME) and/or inadequate priming of tumor-specific T cells. Preclinical and clinical studies suggest that radiopharmaceutical therapy (RPT) may overcome such challenges, but an optimal approach to RPT dosing has not been clarified in combination with ICIs. Conventional RPT dosimetry emphasizes mean absorbed radiation doses in tumors and normal tissues, neglecting the spatial distribution of this dose in the TME. We hypothesize that RPT dose heterogeneity in tumors may be leveraged to initiate spatially restricted immuno-radiobiological effects in TME that potentiate antitumor immunity when injecting an activity that delivers high dose (V10%>20 Gy) while also preserving low dose regions (V90%<2.5 Gy) in the TME and not inducing systemic lymphopenia. In studies using lutetium-177 RPT in combination with ICIs, administered activities that met these dosimetric optimization metrics occurred at different mean tumor doses for different RPT agents and different models, yet each achieved therapeutic efficacy in poorly immunogenic murine tumors. Spatial transcriptomics at day 7 after RPT revealed heterogeneous distribution of tumor cell markers with distinct dose-response profiles and localization of dendritic cell (DC) migratory markers in regions of moderate/high dose response marker expression. Combination therapy sustained conventional type 1 DC (cDC1) activation in tumor draining lymph nodes and promoted systemic expansion of antigen-specific CD8 T cells, while serial biopsies revealed effector T cell recruitment and inflammatory cytokine expression in the TME. Optimized intratumoral dose heterogeneity may enable and predict response to ICIs when combined with RPT in tumors not responding adequately to ICIs alone.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-10-28
DOI
https://doi.org/10.64898/2026.10.27.762270
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Optimized dosing of spatially heterogeneous radiopharmaceutical therapy reprograms poorly immunogenic tumors to enhance response to immune checkpoint blockade

Ohyun Kwon, Tracy J. Berg, Paul A. Clark, Michael Antonelli et al.
5 links
bioRxiv (Cold Spring Harbor Laboratory)
Radiopharmaceutical Chemistry and Applications
preprint

Optimized dosing of spatially heterogeneous radiopharmaceutical therapy reprograms poorly immunogenic tumors to enhance response to immune checkpoint blockade

Ohyun Kwon, Tracy J. Berg, Paul A. Clark, Michael Antonelli, Zachary Scott Morris, Adedamola O. Adeniyi, Reinier Hernandez, Bryan P. Bednarz, Maya E. Takashima, Campbell Haasch, Yujuan Wang, Irene Ong, Wonjong Jin, Jamey Weichert, Malick Bio Idrissou, Zachary Danaceau
preprint en

Abstract

Immune checkpoint inhibitors (ICIs) are ineffective in patients with poorly immunogenic tumors due to exclusion or exhaustion of effector T cells in the tumor microenvironment (TME) and/or inadequate priming of tumor-specific T cells. Preclinical and clinical studies suggest that radiopharmaceutical therapy (RPT) may overcome such challenges, but an optimal approach to RPT dosing has not been clarified in combination with ICIs. Conventional RPT dosimetry emphasizes mean absorbed radiation doses in tumors and normal tissues, neglecting the spatial distribution of this dose in the TME. We hypothesize that RPT dose heterogeneity in tumors may be leveraged to initiate spatially restricted immuno-radiobiological effects in TME that potentiate antitumor immunity when injecting an activity that delivers high dose (V10%>20 Gy) while also preserving low dose regions (V90%<2.5 Gy) in the TME and not inducing systemic lymphopenia. In studies using lutetium-177 RPT in combination with ICIs, administered activities that met these dosimetric optimization metrics occurred at different mean tumor doses for different RPT agents and different models, yet each achieved therapeutic efficacy in poorly immunogenic murine tumors. Spatial transcriptomics at day 7 after RPT revealed heterogeneous distribution of tumor cell markers with distinct dose-response profiles and localization of dendritic cell (DC) migratory markers in regions of moderate/high dose response marker expression. Combination therapy sustained conventional type 1 DC (cDC1) activation in tumor draining lymph nodes and promoted systemic expansion of antigen-specific CD8 T cells, while serial biopsies revealed effector T cell recruitment and inflammatory cytokine expression in the TME. Optimized intratumoral dose heterogeneity may enable and predict response to ICIs when combined with RPT in tumors not responding adequately to ICIs alone.

bioRxiv (Cold Spring Harbor Laboratory)
University of Wisconsin–Madison (US)
University of Wisconsin Carbone Cancer Center, National Institutes of Health, National Cancer Institute
Good health and well-being
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon