Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM)

In the Kazakhstan Material Testing Tokamak (KTM), additional plasma heating will be achieved by injecting power in the ion cyclotron resonance frequency range using four identical generators, each delivering 2 MW of output power. Prior to transitioning the KTM into regular operation, it is necessary to tune these generators using a load equivalent that simulates plasma-like operating conditions. This article presents the electrodynamic design and analysis of a load equivalent capable of absorbing up to 2 MW of high-frequency power. The geometry and key parameters of the load equivalent for the additional high-frequency (HF) plasma heating system of the KTM tokamak are defined. The calculations are based on the assumption that the optimal solution is to construct the load equivalent as a resonator containing a saline aqueous solution absorber housed in a tank with a dielectric window. A dielectric material with high permittivity is proposed for use in the resonator structure. The results demonstrate that the developed load equivalent enables effective testing and tuning of the high-power generators, thus ensuring the readiness of the additional power injection system for scheduled activation on the KTM tokamak. Two plasma load equivalent (PLE) configurations were investigated for different bench-testing purposes. The large PLE was optimized for high RF power absorption in the standing-wave regime, whereas the small PLE was designed to provide a low-impedance loading condition for antenna-matching tests in preparation for plasma operation.

Authors

Institutions

Publication Details

Journal
Plasma
Published
2026-10-28
DOI
https://doi.org/10.3390/plasma9040045
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM)

В. Б. Минаев, D. B. Zarva, Nurzhan Ye. Mukhamedov, K. Zhenis et al.
1 links
Plasma
Magnetic confinement fusion research
article

Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM)

В. Б. Минаев, D. B. Zarva, Nurzhan Ye. Mukhamedov, K. Zhenis, Ye. Kashikbayev, A. V. Gulkin, S. Kotov, Saule Mukeneva, Anuar Kusainov, Baurzhan Chektybayev, Dmitriy Olkhovik, Maxat Bekmuldin, Vladimir Solokha, Andrey Mareev, Valeriy Dyachenko
article en

Abstract

In the Kazakhstan Material Testing Tokamak (KTM), additional plasma heating will be achieved by injecting power in the ion cyclotron resonance frequency range using four identical generators, each delivering 2 MW of output power. Prior to transitioning the KTM into regular operation, it is necessary to tune these generators using a load equivalent that simulates plasma-like operating conditions. This article presents the electrodynamic design and analysis of a load equivalent capable of absorbing up to 2 MW of high-frequency power. The geometry and key parameters of the load equivalent for the additional high-frequency (HF) plasma heating system of the KTM tokamak are defined. The calculations are based on the assumption that the optimal solution is to construct the load equivalent as a resonator containing a saline aqueous solution absorber housed in a tank with a dielectric window. A dielectric material with high permittivity is proposed for use in the resonator structure. The results demonstrate that the developed load equivalent enables effective testing and tuning of the high-power generators, thus ensuring the readiness of the additional power injection system for scheduled activation on the KTM tokamak. Two plasma load equivalent (PLE) configurations were investigated for different bench-testing purposes. The large PLE was optimized for high RF power absorption in the standing-wave regime, whereas the small PLE was designed to provide a low-impedance loading condition for antenna-matching tests in preparation for plasma operation.

PlasmaVol. 9(4)
D. Serikbayev East Kazakhstan State Technical University (KZ), National Nuclear Center of the Republic of Kazakhstan (KZ), Ioffe Institute (RU)
Ministry of Science and Higher Education of the Russian Federation
Affordable and clean energy
Openalex Percentile: Top 17%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon