OXYWILD – Automated versus fixed-dose oxygen therapy during walking in patients with fibrotic interstitial lung diseases: a randomised controlled crossover study

Fibrotic interstitial lung diseases (F-ILDs) are a group of severe, scarring lung diseases often leading to respiratory failure and a need for supplemental oxygen. The symptom burden is high, and patients frequently experience severe dyspnoea, especially during physical exertion. Automated oxygen titration is an emerging treatment modality that continuously adjusts oxygen delivery in response to the patient’s real-time needs. This approach may meet the fluctuating oxygen demands during activity, thus preventing recurrent desaturation episodes and exercise limitation in patients with F-ILD. To compare the effects of automated oxygen titration versus fixed-dose oxygen on dyspnoea during exertion in patients with F-ILD desaturating during walking. In this randomised, controlled, double-blind, crossover trial, participants performed two endurance shuttle walk tests with either fixed-dose or automated oxygen titration via the O2matic equipment, targeting an oxygen saturation of 90–94%. The primary endpoint was dyspnoea at the latest corresponding iso-time; secondary endpoints included walking duration and time spent within the target oxygen saturation range. A mixed-effects analysis was used to compare the two oxygen delivery strategies. In total, 29 participants were included. Participants reported significantly less dyspnoea on the Borg CR10 scale during the endurance shuttle walk test when using automated oxygen titration compared with fixed-dose oxygen (mean difference: -1.5 (95% CI: -2.2 to -0.9). Time spent within the target oxygen saturation range was 25.5% (95% CI: 16.5 to 34.6) longer with automated titration, and walking duration was significantly prolonged compared to fixed-dose oxygen with a mean difference of 91.4 s (95% CI: 12.0 to 179.8). Improving oxygenation by automated oxygen titration during a walking test significantly reduced dyspnoea compared to fixed-dose oxygen in F-ILD patients with exercise-induced hypoxemia. Tailoring oxygen delivery seems to provide clinical benefits and improves patient experience when prescribing ambulatory oxygen. Clinicians and researchers are encouraged to focus on a more individualized approach in practice and future studies. Registration number: NCT06465654, Date of registration: 27/05 -2024.

Authors

Institutions

Publication Details

Journal
Respiratory Research
Published
2026-10-29
DOI
https://doi.org/10.1186/s12931-026-03953-3
Primary Topic
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OXYWILD – Automated versus fixed-dose oxygen therapy during walking in patients with fibrotic interstitial lung diseases: a randomised controlled crossover study

Ejvind Frausing Hansen, Elisabeth M. Bendstrup, Sissel Brix Kronborg-White, Janne Hastrup Jensen et al.
3 links
Respiratory Research
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
article

OXYWILD – Automated versus fixed-dose oxygen therapy during walking in patients with fibrotic interstitial lung diseases: a randomised controlled crossover study

Ejvind Frausing Hansen, Elisabeth M. Bendstrup, Sissel Brix Kronborg-White, Janne Hastrup Jensen, Linette Marie Kofod, Lotte Sørensen, Thomas Prior
article en

Abstract

Fibrotic interstitial lung diseases (F-ILDs) are a group of severe, scarring lung diseases often leading to respiratory failure and a need for supplemental oxygen. The symptom burden is high, and patients frequently experience severe dyspnoea, especially during physical exertion. Automated oxygen titration is an emerging treatment modality that continuously adjusts oxygen delivery in response to the patient’s real-time needs. This approach may meet the fluctuating oxygen demands during activity, thus preventing recurrent desaturation episodes and exercise limitation in patients with F-ILD. To compare the effects of automated oxygen titration versus fixed-dose oxygen on dyspnoea during exertion in patients with F-ILD desaturating during walking. In this randomised, controlled, double-blind, crossover trial, participants performed two endurance shuttle walk tests with either fixed-dose or automated oxygen titration via the O2matic equipment, targeting an oxygen saturation of 90–94%. The primary endpoint was dyspnoea at the latest corresponding iso-time; secondary endpoints included walking duration and time spent within the target oxygen saturation range. A mixed-effects analysis was used to compare the two oxygen delivery strategies. In total, 29 participants were included. Participants reported significantly less dyspnoea on the Borg CR10 scale during the endurance shuttle walk test when using automated oxygen titration compared with fixed-dose oxygen (mean difference: -1.5 (95% CI: -2.2 to -0.9). Time spent within the target oxygen saturation range was 25.5% (95% CI: 16.5 to 34.6) longer with automated titration, and walking duration was significantly prolonged compared to fixed-dose oxygen with a mean difference of 91.4 s (95% CI: 12.0 to 179.8). Improving oxygenation by automated oxygen titration during a walking test significantly reduced dyspnoea compared to fixed-dose oxygen in F-ILD patients with exercise-induced hypoxemia. Tailoring oxygen delivery seems to provide clinical benefits and improves patient experience when prescribing ambulatory oxygen. Clinicians and researchers are encouraged to focus on a more individualized approach in practice and future studies. Registration number: NCT06465654, Date of registration: 27/05 -2024.

Respiratory Research
Aarhus University (DK), Aalborg University Hospital (DK), Hvidovre Hospital (DK), Aarhus University Hospital (DK), Copenhagen University Hospital (DK), Aalborg University (DK)
Good health and well-being
Openalex Percentile: Top 13%
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon