CFRP Strengthening for Progressive Collapse Mitigation of RC Flat Slabs

This study evaluates different strengthening arrangements of externally bonded carbon fibre-reinforced polymer (CFRP) strips for mitigating progressive collapse of reinforced concrete flat slabs following column failure. Using a well-calibrated three-dimensional numerical model based on the Applied Element Method, parameters including CFRP strip position, width, length, spacing, multiplicity, and fibre orientation were systematically investigated to evaluate their influence on flat slab strength, compressive membrane action, tensile membrane action, punching resistance, catenary action, deflection at peak catenary load, energy dissipation, residual strength, strain distribution, and contribution of slab column and middle strips in resisting progressive collapse. This study highlighted that CFRP strengthening arrangements can modify stress and strain redistributions and load-transfer mechanisms, leading to transforming the slab behaviour from a localized slab–column connection resistance into a global slab-wide load-resisting mechanism capable of mobilizing alternative load paths overarching a larger portion of the slab area to mitigate progressive collapse. Under the adopted ideal-bond assumption, the 100 mm-wide strip-length series increased peak catenary load by up to 89.92% and load-deflection energy to peak catenary load by up to 153.51% relative to the unstrengthened control. The findings also demonstrated that optimizing strengthening arrangement was primarily a load-transfer path problem rather than a material-quantity problem, where strategically configured arrangement can optimally enhance the flat slab resistance mechanism to progressive collapse. Overall, this study provides new insights into the mechanistic role of strengthening arrangement parameters in controlling the transformation from localized slab–column connection resistance to a more robust global slab-wide resistance mechanism capable of mitigating flat slab progressive collapse.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-10-28
DOI
https://doi.org/10.3390/buildings16214301
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFRP Strengthening for Progressive Collapse Mitigation of RC Flat Slabs

Bilal El-Ariss, Said A. Elkholy, Omer Ghunaim
Buildings
Structural Response to Dynamic Loads
article

CFRP Strengthening for Progressive Collapse Mitigation of RC Flat Slabs

Bilal El-Ariss, Said A. Elkholy, Omer Ghunaim
article en

Abstract

This study evaluates different strengthening arrangements of externally bonded carbon fibre-reinforced polymer (CFRP) strips for mitigating progressive collapse of reinforced concrete flat slabs following column failure. Using a well-calibrated three-dimensional numerical model based on the Applied Element Method, parameters including CFRP strip position, width, length, spacing, multiplicity, and fibre orientation were systematically investigated to evaluate their influence on flat slab strength, compressive membrane action, tensile membrane action, punching resistance, catenary action, deflection at peak catenary load, energy dissipation, residual strength, strain distribution, and contribution of slab column and middle strips in resisting progressive collapse. This study highlighted that CFRP strengthening arrangements can modify stress and strain redistributions and load-transfer mechanisms, leading to transforming the slab behaviour from a localized slab–column connection resistance into a global slab-wide load-resisting mechanism capable of mobilizing alternative load paths overarching a larger portion of the slab area to mitigate progressive collapse. Under the adopted ideal-bond assumption, the 100 mm-wide strip-length series increased peak catenary load by up to 89.92% and load-deflection energy to peak catenary load by up to 153.51% relative to the unstrengthened control. The findings also demonstrated that optimizing strengthening arrangement was primarily a load-transfer path problem rather than a material-quantity problem, where strategically configured arrangement can optimally enhance the flat slab resistance mechanism to progressive collapse. Overall, this study provides new insights into the mechanistic role of strengthening arrangement parameters in controlling the transformation from localized slab–column connection resistance to a more robust global slab-wide resistance mechanism capable of mitigating flat slab progressive collapse.

BuildingsVol. 16(21)
United Arab Emirates University (AE), Fayoum University (EG)
United Arab Emirates University
Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.