A novel integrated workflow for deep geothermal reservoir characterization using core data, optimized coupled petrophysical–seismic modeling, and machine learning: A case study from the SW Paris Basin, France

The Paris Basin hosts one of the longest-operating deep geothermal systems in Europe, with approximately 50 geothermal doublets exploiting the Middle Jurassic Dogger carbonate and Lower Cretaceous Albian siliciclastic aquifers and supplying nearly 2 TWh of renewable heat annually. Despite extensive geological and geophysical investigations, predicting reservoir facies, heterogeneity, and transmissivity remains highly uncertain. This study presents a physics-guided, multi-scale workflow that integrates petrophysics, rock physics, seismic inversion, and stochastic reservoir modeling to characterize the Dogger, Oxfordian, and Triassic geothermal reservoirs of the Paris Basin. The workflow combines four components: (i) estimation of mineral volumes and total porosity ( ϕ total ) using a hybrid statistical–machine learning approach calibrated with X-ray diffraction (XRD) measurements; (ii) joint Monte Carlo inversion of water saturation ( S w ) and formation water resistivity ( R w ) under petrophysical constraints; (iii) generation of a rock-physics-guided synthetic pseudo-well catalogue and corresponding pre-stack Zoeppritz angle gathers, in which XRD-calibrated mineral end-members and petrophysically consistent elastic trends impose physical structure absent from a purely data-driven training set; and (iv) convolutional neural network (CNN) prediction of clay volume ( V clay ), total porosity, and effective porosity ( ϕ eff ) from pre-stack seismic data, pretrained on this synthetic catalogue and fine-tuned via transfer learning on seven real wells. Three additional wells, excluded from transfer learning, were reserved for semi-blind validation. At the calibration wells, R 2 ranges from 0.858 to 0.985 across the three properties, with normalized mean-square error (NMSE) of 1.8%–18.0% and root-mean-square error (RMSE) below 0.043. At the semi-blind wells, performance varies with local well-to-seismic tie quality: one well reproduces calibration-level statistics ( R 2 > 0.92 , NMSE < 10%), while the other two show progressively degraded performance ( R 2 as low as 0.41, NMSE up to 113%), consistent with documented tie-quality issues at those locations rather than a general failure to generalize. The predicted properties reproduce major depositional trends, including Oxfordian lateral continuity and Dogger reservoir compartmentalization, without explicit stratigraphic conditioning. Effective porosity predicted along 1,990 km of interpreted 2D seismic profiles was then integrated into stochastic three-dimensional reservoir modeling, generating 100 equiprobable realizations that represent reservoir heterogeneity and uncertainty while remaining consistent with well observations and regional seismic trends.

Authors

Institutions

Publication Details

Journal
Geothermics
Published
2026-10-28
DOI
https://doi.org/10.1016/j.geothermics.2026.103880
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel integrated workflow for deep geothermal reservoir characterization using core data, optimized coupled petrophysical–seismic modeling, and machine learning: A case study from the SW Paris Basin, France

K. Siraev, Laurent Beccaletto, Agathe Faure, Shervin Rasoulzadeh et al.
1 links
Geothermics
Geothermal Energy Systems and Applications
article

A novel integrated workflow for deep geothermal reservoir characterization using core data, optimized coupled petrophysical–seismic modeling, and machine learning: A case study from the SW Paris Basin, France

K. Siraev, Laurent Beccaletto, Agathe Faure, Shervin Rasoulzadeh, Joshua Pwavodi, Alexandre Stopin, Alexandre Ortiz, Laure Capar, A. Bordenave, Stéphane Marc, Nicolas Maubec, Camille Maurel, Ali Moradi Tehrani, Benoît Issautier, Justine Briais, Éric Lasseur, Amit Singh, Pavel Didenko
article en

Abstract

The Paris Basin hosts one of the longest-operating deep geothermal systems in Europe, with approximately 50 geothermal doublets exploiting the Middle Jurassic Dogger carbonate and Lower Cretaceous Albian siliciclastic aquifers and supplying nearly 2 TWh of renewable heat annually. Despite extensive geological and geophysical investigations, predicting reservoir facies, heterogeneity, and transmissivity remains highly uncertain. This study presents a physics-guided, multi-scale workflow that integrates petrophysics, rock physics, seismic inversion, and stochastic reservoir modeling to characterize the Dogger, Oxfordian, and Triassic geothermal reservoirs of the Paris Basin. The workflow combines four components: (i) estimation of mineral volumes and total porosity ( ϕ total ) using a hybrid statistical–machine learning approach calibrated with X-ray diffraction (XRD) measurements; (ii) joint Monte Carlo inversion of water saturation ( S w ) and formation water resistivity ( R w ) under petrophysical constraints; (iii) generation of a rock-physics-guided synthetic pseudo-well catalogue and corresponding pre-stack Zoeppritz angle gathers, in which XRD-calibrated mineral end-members and petrophysically consistent elastic trends impose physical structure absent from a purely data-driven training set; and (iv) convolutional neural network (CNN) prediction of clay volume ( V clay ), total porosity, and effective porosity ( ϕ eff ) from pre-stack seismic data, pretrained on this synthetic catalogue and fine-tuned via transfer learning on seven real wells. Three additional wells, excluded from transfer learning, were reserved for semi-blind validation. At the calibration wells, R 2 ranges from 0.858 to 0.985 across the three properties, with normalized mean-square error (NMSE) of 1.8%–18.0% and root-mean-square error (RMSE) below 0.043. At the semi-blind wells, performance varies with local well-to-seismic tie quality: one well reproduces calibration-level statistics ( R 2 > 0.92 , NMSE < 10%), while the other two show progressively degraded performance ( R 2 as low as 0.41, NMSE up to 113%), consistent with documented tie-quality issues at those locations rather than a general failure to generalize. The predicted properties reproduce major depositional trends, including Oxfordian lateral continuity and Dogger reservoir compartmentalization, without explicit stratigraphic conditioning. Effective porosity predicted along 1,990 km of interpreted 2D seismic profiles was then integrated into stochastic three-dimensional reservoir modeling, generating 100 equiprobable realizations that represent reservoir heterogeneity and uncertainty while remaining consistent with well observations and regional seismic trends.

GeothermicsVol. 143
Bureau de Recherches Géologiques et Minières (FR)
Conseil Régional, Île-de-France, Agence de la transition écologique
Affordable and clean energy
Openalex Percentile: Top 35%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon