Determination of deposition rates from indoor particle dynamics

Particle deposition is a key removal mechanism affecting indoor particle concentrations. Quantifying deposition under real-world conditions remains challenging because measurements are affected by outdoor variability, indoor emissions, air leakage, and ventilation. Reliable characterization of size-dependent deposition is nevertheless essential for accurate modeling of indoor particle dynamics. This study evaluates two approaches for estimating size-resolved deposition loss coefficients in an unoccupied residence with stable mechanical exhaust ventilation. Indoor and outdoor particle number concentrations were measured in a single-storey 63 m2 terraced house equipped with mechanical exhaust ventilation during a one-week campaign in spring 2025. Replacement outdoor air entered through four purpose-installed outdoor air inlet vents in the external walls. During the deposition experiment, the vents were operated without filters, providing an unobstructed outdoor-air pathway. Measurements were conducted under unoccupied conditions to enable controlled assessment of deposition. The particle number concentrations were continuously monitored using a scanning mobility particle sizer (SMPS) and an optical particle counter (OPC). Size-resolved particle deposition loss rates were estimated using two separate methods: (i) dynamic modeling, in which model-predicted indoor number concentrations were fitted to the measured data and (ii) an I/O-ratio method, in which deposition loss rates were calculated for individual particle size bins from time-averaged indoor-to-outdoor (I/O) concentration ratios. Deposition loss coefficients were determined for particle sizes between 0.01 and 2.5 µm. The resulting deposition loss rate curve exhibited a U-shaped dependence on particle diameter, with a minimum at approximately 0.1–0.2 µm. Both methods produced comparable deposition loss coefficients and consistent size-dependent behavior, provided that the sampling duration was sufficient for stable I/O ratios. Deposition loss rates ranged from 0.15 to 0.75 h−1.

Authors

Institutions

Publication Details

Journal
Aerosol Science and Technology
Published
2026-10-28
DOI
https://doi.org/10.1080/02786826.2026.2754776
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of deposition rates from indoor particle dynamics

Ilpo K. Kulmala, Arto J. Säämänen, N. Siilin, J. Hakala et al.
Aerosol Science and Technology
Indoor Air Quality and Microbial Exposure
article

Determination of deposition rates from indoor particle dynamics

Ilpo K. Kulmala, Arto J. Säämänen, N. Siilin, J. Hakala, M. Kultanen, I. Ehder-Gahm
article en

Abstract

Particle deposition is a key removal mechanism affecting indoor particle concentrations. Quantifying deposition under real-world conditions remains challenging because measurements are affected by outdoor variability, indoor emissions, air leakage, and ventilation. Reliable characterization of size-dependent deposition is nevertheless essential for accurate modeling of indoor particle dynamics. This study evaluates two approaches for estimating size-resolved deposition loss coefficients in an unoccupied residence with stable mechanical exhaust ventilation. Indoor and outdoor particle number concentrations were measured in a single-storey 63 m2 terraced house equipped with mechanical exhaust ventilation during a one-week campaign in spring 2025. Replacement outdoor air entered through four purpose-installed outdoor air inlet vents in the external walls. During the deposition experiment, the vents were operated without filters, providing an unobstructed outdoor-air pathway. Measurements were conducted under unoccupied conditions to enable controlled assessment of deposition. The particle number concentrations were continuously monitored using a scanning mobility particle sizer (SMPS) and an optical particle counter (OPC). Size-resolved particle deposition loss rates were estimated using two separate methods: (i) dynamic modeling, in which model-predicted indoor number concentrations were fitted to the measured data and (ii) an I/O-ratio method, in which deposition loss rates were calculated for individual particle size bins from time-averaged indoor-to-outdoor (I/O) concentration ratios. Deposition loss coefficients were determined for particle sizes between 0.01 and 2.5 µm. The resulting deposition loss rate curve exhibited a U-shaped dependence on particle diameter, with a minimum at approximately 0.1–0.2 µm. Both methods produced comparable deposition loss coefficients and consistent size-dependent behavior, provided that the sampling duration was sufficient for stable I/O ratios. Deposition loss rates ranged from 0.15 to 0.75 h−1.

Aerosol Science and Technology
VTT Technical Research Centre of Finland (FI), Aalto University (FI)
Business Finland
Openalex Percentile: Top 18%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon