Diagnostic performance of clinical photon-counting CT in the assessment of peri-implantitis – an ex vivo diagnostic accuracy study

Abstract Purpose To evaluate the diagnostic performance of photon-counting computed tomography (PCCT) for the assessment of peri-implant bone defects and to compare it with cone-beam computed tomography (CBCT) at comparable radiation doses. Methods Circular peri-implant defects were artificially created around 27 titanium implants placed in nine porcine mandibles. Defect morphology was digitized using an intraoral scanner (STL, stereolithography file format) as reference standard. Specimens were imaged with high-resolution CBCT (HD-CBCT) and PCCT at clinically commonly used dose levels, which were nearly identical for both modalities to ensure comparability. Vertical defect depth and horizontal defect width were measured at predefined locations by two calibrated readers. Agreement with the reference standard was assessed using paired statistical testing, Bland-Altman analysis, mean absolute error (MAE), relative error metrics, and intraclass correlation coefficients (ICC). Results For vertical defect depth (mean reference 4.68 ± 2.20 mm), PCCT demonstrated significantly lower MAE than CBCT (0.14 mm vs. 0.67 mm; p < 0.001) and narrower limits of agreement. Relative absolute error was 4.3% for PCCT and 17.4% for CBCT. For horizontal defect width (mean reference 0.99 ± 0.39 mm), both modalities slightly underestimated the defect width compared to the reference standard of the oral scanner. However, PCCT showed lower MAE (0.077 mm vs. 0.18 mm; p < 0.001) and reduced proportional variability. Intra- and inter-reader reliability were consistently higher for PCCT (ICC up to 0.994) compared with CBCT. Conclusions Within the limitations of this ex vivo model, PCCT provided more accurate and reproducible three-dimensional measurements of standardized peri-implant bone defects than CBCT. These findings need to be confirmed by further in vivo studies to determine its clinical diagnostic value and potential impact on treatment planning.

Authors

Institutions

Publication Details

Journal
International Journal of Implant Dentistry
Published
2026-10-28
DOI
https://doi.org/10.1186/s40729-026-00722-1
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic performance of clinical photon-counting CT in the assessment of peri-implantitis – an ex vivo diagnostic accuracy study

Anna Felten, Christian Mertens, Marc Kachelrieß, Maurice Ruetters et al.
2 links
International Journal of Implant Dentistry
Dental Radiography and Imaging
article

Diagnostic performance of clinical photon-counting CT in the assessment of peri-implantitis – an ex vivo diagnostic accuracy study

Anna Felten, Christian Mertens, Marc Kachelrieß, Maurice Ruetters, Alexander-Nicolaus Spies, Stefan Sawall, Tisun Kim, Благовест Благоев, Heinz-Peter Schlemmer, Stefan Schoenberg, Matthias Froelich
article en

Abstract

Abstract Purpose To evaluate the diagnostic performance of photon-counting computed tomography (PCCT) for the assessment of peri-implant bone defects and to compare it with cone-beam computed tomography (CBCT) at comparable radiation doses. Methods Circular peri-implant defects were artificially created around 27 titanium implants placed in nine porcine mandibles. Defect morphology was digitized using an intraoral scanner (STL, stereolithography file format) as reference standard. Specimens were imaged with high-resolution CBCT (HD-CBCT) and PCCT at clinically commonly used dose levels, which were nearly identical for both modalities to ensure comparability. Vertical defect depth and horizontal defect width were measured at predefined locations by two calibrated readers. Agreement with the reference standard was assessed using paired statistical testing, Bland-Altman analysis, mean absolute error (MAE), relative error metrics, and intraclass correlation coefficients (ICC). Results For vertical defect depth (mean reference 4.68 ± 2.20 mm), PCCT demonstrated significantly lower MAE than CBCT (0.14 mm vs. 0.67 mm; p < 0.001) and narrower limits of agreement. Relative absolute error was 4.3% for PCCT and 17.4% for CBCT. For horizontal defect width (mean reference 0.99 ± 0.39 mm), both modalities slightly underestimated the defect width compared to the reference standard of the oral scanner. However, PCCT showed lower MAE (0.077 mm vs. 0.18 mm; p < 0.001) and reduced proportional variability. Intra- and inter-reader reliability were consistently higher for PCCT (ICC up to 0.994) compared with CBCT. Conclusions Within the limitations of this ex vivo model, PCCT provided more accurate and reproducible three-dimensional measurements of standardized peri-implant bone defects than CBCT. These findings need to be confirmed by further in vivo studies to determine its clinical diagnostic value and potential impact on treatment planning.

International Journal of Implant DentistryVol. 12(1)
German Cancer Research Center (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), University Medical Centre Mannheim (DE)
Good health and well-being
Openalex Percentile: Top 11%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon