Physicochemical and Mechanical Characterization of Silk and PGLA Dental Sutures Following Humic-Acid-Containing Surface Treatment

Surface coating may influence the physicochemical and mechanical properties of surgical sutures. This study was conducted to characterize the changes associated with a humic-acid-containing alginate coating applied to silk and poly(glycolide-co-lactide) (PGLA) sutures in two sizes (3-0 and 4-0). Untreated sutures served as controls. Surface-related spectral changes were examined using Fourier-transform infrared (FTIR) spectroscopy, while mechanical properties were evaluated via tensile testing in accordance with EN ISO 2062. Maximum tensile force and elongation at break were recorded. FTIR analysis revealed changes in the intensity and breadth of selected absorption bands, particularly those associated with O–H and C=O groups, after the coating was applied. These findings indicated treatment-associated spectral changes but did not independently confirm humic acid incorporation or coating stability. The maximum tensile force was lower in treated silk sutures than in untreated controls for both size 3-0 (22.6 ± 3.68 N vs. 17.8 ± 1.35 N; p = 0.140) and size 4-0 (12.8 ± 1.21 N vs. 10.6 ± 2.56 N; p = 0.276), although neither difference was statistically significant. For PGLA sutures, no statistically significant difference was observed for size 3-0 (27.7 ± 2.80 N vs. 27.6 ± 2.56 N; p = 0.966). In contrast, the size 4-0 PGLA sutures exhibited a higher maximum tensile force following treatment (14.2 ± 1.85 N vs. 21.1 ± 2.45 N; p = 0.021). Elongation at break increased in the treated size 3-0 silk sutures (16.0 ± 0.91% vs. 20.3 ± 1.10%; p = 0.007) and decreased in the treated size 4-0 silk sutures (19.3 ± 1.26% vs. 14.8 ± 1.75%; p = 0.027). No statistically significant differences in elongation were found for size 3-0 PGLA (32.1 ± 1.16% vs. 28.4 ± 2.21%; p = 0.082) or size 4-0 PGLA sutures (31.4 ± 1.88% vs. 30.8 ± 1.24%; p = 0.672). These preliminary findings indicate that the humic-acid-containing alginate coating procedure was associated with spectral changes and different mechanical responses in silk and PGLA sutures.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-10-28
DOI
https://doi.org/10.3390/polym18212676
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physicochemical and Mechanical Characterization of Silk and PGLA Dental Sutures Following Humic-Acid-Containing Surface Treatment

Mehmet Kılınç, Halil Çelik, Ali Merdji, Aysun Akpınar et al.
Polymers
Surgical Sutures and Adhesives
article

Physicochemical and Mechanical Characterization of Silk and PGLA Dental Sutures Following Humic-Acid-Containing Surface Treatment

Mehmet Kılınç, Halil Çelik, Ali Merdji, Aysun Akpınar, Zeynep Ceren Çelik, Sandipan Roy
article en

Abstract

Surface coating may influence the physicochemical and mechanical properties of surgical sutures. This study was conducted to characterize the changes associated with a humic-acid-containing alginate coating applied to silk and poly(glycolide-co-lactide) (PGLA) sutures in two sizes (3-0 and 4-0). Untreated sutures served as controls. Surface-related spectral changes were examined using Fourier-transform infrared (FTIR) spectroscopy, while mechanical properties were evaluated via tensile testing in accordance with EN ISO 2062. Maximum tensile force and elongation at break were recorded. FTIR analysis revealed changes in the intensity and breadth of selected absorption bands, particularly those associated with O–H and C=O groups, after the coating was applied. These findings indicated treatment-associated spectral changes but did not independently confirm humic acid incorporation or coating stability. The maximum tensile force was lower in treated silk sutures than in untreated controls for both size 3-0 (22.6 ± 3.68 N vs. 17.8 ± 1.35 N; p = 0.140) and size 4-0 (12.8 ± 1.21 N vs. 10.6 ± 2.56 N; p = 0.276), although neither difference was statistically significant. For PGLA sutures, no statistically significant difference was observed for size 3-0 (27.7 ± 2.80 N vs. 27.6 ± 2.56 N; p = 0.966). In contrast, the size 4-0 PGLA sutures exhibited a higher maximum tensile force following treatment (14.2 ± 1.85 N vs. 21.1 ± 2.45 N; p = 0.021). Elongation at break increased in the treated size 3-0 silk sutures (16.0 ± 0.91% vs. 20.3 ± 1.10%; p = 0.007) and decreased in the treated size 4-0 silk sutures (19.3 ± 1.26% vs. 14.8 ± 1.75%; p = 0.027). No statistically significant differences in elongation were found for size 3-0 PGLA (32.1 ± 1.16% vs. 28.4 ± 2.21%; p = 0.082) or size 4-0 PGLA sutures (31.4 ± 1.88% vs. 30.8 ± 1.24%; p = 0.672). These preliminary findings indicate that the humic-acid-containing alginate coating procedure was associated with spectral changes and different mechanical responses in silk and PGLA sutures.

PolymersVol. 18(21)
Bursa Uludağ Üni̇versi̇tesi̇ (TR), SRM Institute of Science and Technology (IN), Giresun University (TR), Istinye University (TR), Université Mustapha Stambouli de Mascara (DZ), Université Djilali de Sidi Bel Abbès (DZ), Laboratory of Mechanics Physics of Materials (DZ)
Good health and well-being
Openalex Percentile: Top 10%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon