Analytical Evaluation of Urinary CXCL10 as a Biomarker for Kidney Allograft Rejection

BACKGROUND: Urinary C-X-C motif chemokine ligand 10 (CXCL10), a chemokine for leukocyte recruitment, is a sensitive and specific biomarker for diagnosing kidney transplant rejection. We performed comprehensive test validations for CXCL10 using urine samples with the Meso Quickplex SQ 120, following CLSI guidelines. METHODS: Precision, linearity, recovery, freeze-thaw cycles, interference from hemoglobin, triglyceride, conjugated bilirubin, and protein, as well as lot-to-lot variation were assessed. Fresh urine samples were held at room temperature (RT) for 1, 2, 4 h or at 4°C for 1, 2, 4, 24 h before processing, then centrifuged at different speeds (400, 800, 1500, and 2000g) and for different time periods (6, 10, and 20 min) at the same temperature. RESULTS: Within-run and between-run precision were <7% and <15% for both QC and human urine, with the latter being slightly larger. Linearity was up to 900 ng/L with a limit of quantitation of 2.45 ng/L. The recovery for urinary CXCL10 ranged from 94% to 102%. CXCL10 was stable for up to 6 freeze-thaw cycles. No interferences were detected with proteinuria and bilirubinuria. Lipuria and severe hematuria (hemoglobin, Hb = 5 g/L) were found to interfere with CXCL10 measurements. CXCL10 is stable in unprocessed urine stored at RT for 4 h and at 4°C for 24 h. Various centrifugation time and speeds had insignificant effects on CXCL10 measurement. CONCLUSIONS: Urinary CXCL10 exhibits robust reproducibility and can be handled the same way as other clinical urine analytes, indicating it is suitable as a diagnostic biomarker to assess patients after kidney transplant.

Authors

Institutions

Publication Details

Journal
The Journal of Applied Laboratory Medicine
Published
2026-10-28
DOI
https://doi.org/10.1093/jalm/jfag163
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Evaluation of Urinary CXCL10 as a Biomarker for Kidney Allograft Rejection

Elsa Ho, Tom David Blydt‐Hansen, Manoela de Paula Ferreira, Li Wang
1 links
The Journal of Applied Laboratory Medicine
Renal Transplantation Outcomes and Treatments
article

Analytical Evaluation of Urinary CXCL10 as a Biomarker for Kidney Allograft Rejection

Elsa Ho, Tom David Blydt‐Hansen, Manoela de Paula Ferreira, Li Wang
article en

Abstract

BACKGROUND: Urinary C-X-C motif chemokine ligand 10 (CXCL10), a chemokine for leukocyte recruitment, is a sensitive and specific biomarker for diagnosing kidney transplant rejection. We performed comprehensive test validations for CXCL10 using urine samples with the Meso Quickplex SQ 120, following CLSI guidelines. METHODS: Precision, linearity, recovery, freeze-thaw cycles, interference from hemoglobin, triglyceride, conjugated bilirubin, and protein, as well as lot-to-lot variation were assessed. Fresh urine samples were held at room temperature (RT) for 1, 2, 4 h or at 4°C for 1, 2, 4, 24 h before processing, then centrifuged at different speeds (400, 800, 1500, and 2000g) and for different time periods (6, 10, and 20 min) at the same temperature. RESULTS: Within-run and between-run precision were <7% and <15% for both QC and human urine, with the latter being slightly larger. Linearity was up to 900 ng/L with a limit of quantitation of 2.45 ng/L. The recovery for urinary CXCL10 ranged from 94% to 102%. CXCL10 was stable for up to 6 freeze-thaw cycles. No interferences were detected with proteinuria and bilirubinuria. Lipuria and severe hematuria (hemoglobin, Hb = 5 g/L) were found to interfere with CXCL10 measurements. CXCL10 is stable in unprocessed urine stored at RT for 4 h and at 4°C for 24 h. Various centrifugation time and speeds had insignificant effects on CXCL10 measurement. CONCLUSIONS: Urinary CXCL10 exhibits robust reproducibility and can be handled the same way as other clinical urine analytes, indicating it is suitable as a diagnostic biomarker to assess patients after kidney transplant.

The Journal of Applied Laboratory Medicine
University of British Columbia (CA), BC Children's Hospital (CA), BC Children's Hospital Research Institute (CA)
BC Children's Hospital
Good health and well-being
Openalex Percentile: Top 9%
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon