Photoacoustic phase and intensity dual-modality imaging for characterization of plaque viscoelasticity and lipid composition: a feasibility study

SignificanceRupture of atherosclerotic plaque is the most important cause of sudden death in acute myocardial infarction. Plaque stability is closely related to mechanical characters and histological composition. A dual-modality technique, combining photoacoustic phase imaging (PPI) and intensity imaging (PAI), was developed providing viscoelasticity and lipid component of plaques simultaneously.AimWe aimed to investigate the feasibility of PPI to identify thin-cap fibrous plaques by detecting viscosity-elasticity ratio (VER), to further examine the correlation between VER and the major components of plaque, and ultimately to verify the accuracy of PPI-PAI in assessing plaque types.ApproachPPI-PAI experiments were performed on the aortas of 18 Apolipoprotein E-knockout (ApoE) mice fed with high-fat/high-cholesterol diet. After each experiment, the plaques at the target sites were stained with Oil Red O, Masson, and F4/80 staining to verify the accuracy of the imaging and to further investigate the correlations between VER and lipid core area, fibrous cap thickness, and macrophage content. Finally, conventional statistical methods, such as linear analysis, were used to summarize the experimental data and draw general conclusions.ResultsPPI enables quantitative VER detection of plaques, with thin-cap fibrous plaques exhibiting the highest VER (3.77×10−5∼4.68×10−5 s). There is a high positive correlation between VER and lipid cross-section area (R2=0.81, p<0.0001) and macrophage content (R2=0.75, p<0.0001) in lipid plaque lesions. Likewise, in fibrous plaques, a strong negative correlation (R2=0.71, p<0.0001) is demonstrated between VER and fibrous cap thickness; and a high positive correlation (R2=0.12, p=0.02) between VER and macrophage content. As lipid plaques and thick-cap fibrous plaques may have the same VER values, the combination of PPI and PAI can effectively identify plaque types.ConclusionsPPI facilitates the characterization of thin-cap fibrous plaques by VER measurements, and further combination with PAI can improve the detection rate of distinct plaque types.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Optics
Published
2026-10-28
DOI
https://doi.org/10.1117/1.jbo.32.s1.s14904
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photoacoustic phase and intensity dual-modality imaging for characterization of plaque viscoelasticity and lipid composition: a feasibility study

Yuxuan Liang, Ao Jiang, Yiting Tan, Heng Zhang
1 links
Journal of Biomedical Optics
Photoacoustic and Ultrasonic Imaging
article

Photoacoustic phase and intensity dual-modality imaging for characterization of plaque viscoelasticity and lipid composition: a feasibility study

Yuxuan Liang, Ao Jiang, Yiting Tan, Heng Zhang
article en

Abstract

SignificanceRupture of atherosclerotic plaque is the most important cause of sudden death in acute myocardial infarction. Plaque stability is closely related to mechanical characters and histological composition. A dual-modality technique, combining photoacoustic phase imaging (PPI) and intensity imaging (PAI), was developed providing viscoelasticity and lipid component of plaques simultaneously.AimWe aimed to investigate the feasibility of PPI to identify thin-cap fibrous plaques by detecting viscosity-elasticity ratio (VER), to further examine the correlation between VER and the major components of plaque, and ultimately to verify the accuracy of PPI-PAI in assessing plaque types.ApproachPPI-PAI experiments were performed on the aortas of 18 Apolipoprotein E-knockout (ApoE) mice fed with high-fat/high-cholesterol diet. After each experiment, the plaques at the target sites were stained with Oil Red O, Masson, and F4/80 staining to verify the accuracy of the imaging and to further investigate the correlations between VER and lipid core area, fibrous cap thickness, and macrophage content. Finally, conventional statistical methods, such as linear analysis, were used to summarize the experimental data and draw general conclusions.ResultsPPI enables quantitative VER detection of plaques, with thin-cap fibrous plaques exhibiting the highest VER (3.77×10−5∼4.68×10−5 s). There is a high positive correlation between VER and lipid cross-section area (R2=0.81, p<0.0001) and macrophage content (R2=0.75, p<0.0001) in lipid plaque lesions. Likewise, in fibrous plaques, a strong negative correlation (R2=0.71, p<0.0001) is demonstrated between VER and fibrous cap thickness; and a high positive correlation (R2=0.12, p=0.02) between VER and macrophage content. As lipid plaques and thick-cap fibrous plaques may have the same VER values, the combination of PPI and PAI can effectively identify plaque types.ConclusionsPPI facilitates the characterization of thin-cap fibrous plaques by VER measurements, and further combination with PAI can improve the detection rate of distinct plaque types.

Journal of Biomedical OpticsVol. 32(S1)
Shaoxing University (CN)
Good health and well-being
Openalex Percentile: Top 25%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon