Remote Photoplethysmography-Based HbA1c Estimation for Community Screening of Type 2 Diabetes Mellitus: Screening Tool or Diagnostic Alternative?

Type 2 diabetes mellitus (T2DM) remains a major global health burden, with a high proportion of undiagnosed cases, particularly in community settings with limited access to laboratory testing. Remote photoplethysmography (rPPG) has emerged as a non-invasive, camera-based technology with potential for scalable screening. This study aimed to evaluate the agreement, diagnostic performance, and clinical role of rPPG-derived HbA1c as a screening tool or diagnostic alternative for T2DM. A cross-sectional diagnostic validation study was conducted among adults in a community setting in Semanan Subdistrict, Jakarta. Participants underwent non-contact facial scanning using an rPPG system alongside standard laboratory measurements of HbA1c and blood glucose. Agreement was assessed using Bland–Altman analysis and Cohen’s Kappa. Diagnostic performance was evaluated using sensitivity, specificity, predictive values, and receiver operating characteristic (ROC) curve analysis. rPPG-derived HbA1c showed a significant mean difference compared with laboratory measurements (0.63%; p < 0.001; 95% CI: 0.34–0.93), indicating systematic bias. Categorical agreement was poor (κ = 0.029; p = 0.403). In screening analysis, sensitivity ranged from 65.38% to 97.37%, while specificity ranged from 8.91% to 59.55%, with consistently high negative predictive values (≥82%). ROC analysis demonstrated an AUC of 0.668 (p = 0.008) for diabetes and 0.711 (p < 0.001) for prediabetes, indicating modest to acceptable discriminative ability. rPPG-based HbA1c estimation lacks sufficient agreement for diagnostic use. However, its relatively high sensitivity and scalability suggest that it may warrant further evaluation as a non-invasive screening tool for early detection and population-level risk stratification within mobile health settings.

Authors

Institutions

Publication Details

Journal
Journal of Applied Data Sciences
Published
2026-10-29
DOI
https://doi.org/10.47738/jads.v7i4.1433
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote Photoplethysmography-Based HbA1c Estimation for Community Screening of Type 2 Diabetes Mellitus: Screening Tool or Diagnostic Alternative?

Ernawati Ernawati
Journal of Applied Data Sciences
Non-Invasive Vital Sign Monitoring
article

Remote Photoplethysmography-Based HbA1c Estimation for Community Screening of Type 2 Diabetes Mellitus: Screening Tool or Diagnostic Alternative?

Ernawati Ernawati
article en

Abstract

Type 2 diabetes mellitus (T2DM) remains a major global health burden, with a high proportion of undiagnosed cases, particularly in community settings with limited access to laboratory testing. Remote photoplethysmography (rPPG) has emerged as a non-invasive, camera-based technology with potential for scalable screening. This study aimed to evaluate the agreement, diagnostic performance, and clinical role of rPPG-derived HbA1c as a screening tool or diagnostic alternative for T2DM. A cross-sectional diagnostic validation study was conducted among adults in a community setting in Semanan Subdistrict, Jakarta. Participants underwent non-contact facial scanning using an rPPG system alongside standard laboratory measurements of HbA1c and blood glucose. Agreement was assessed using Bland–Altman analysis and Cohen’s Kappa. Diagnostic performance was evaluated using sensitivity, specificity, predictive values, and receiver operating characteristic (ROC) curve analysis. rPPG-derived HbA1c showed a significant mean difference compared with laboratory measurements (0.63%; p < 0.001; 95% CI: 0.34–0.93), indicating systematic bias. Categorical agreement was poor (κ = 0.029; p = 0.403). In screening analysis, sensitivity ranged from 65.38% to 97.37%, while specificity ranged from 8.91% to 59.55%, with consistently high negative predictive values (≥82%). ROC analysis demonstrated an AUC of 0.668 (p = 0.008) for diabetes and 0.711 (p < 0.001) for prediabetes, indicating modest to acceptable discriminative ability. rPPG-based HbA1c estimation lacks sufficient agreement for diagnostic use. However, its relatively high sensitivity and scalability suggest that it may warrant further evaluation as a non-invasive screening tool for early detection and population-level risk stratification within mobile health settings.

Journal of Applied Data SciencesVol. 7(4)
Tarumanagara University (ID)
Good health and well-being
Openalex Percentile: Top 25%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Remote Photoplethysmography-Based HbA1c Estimation for Community Screening of Type 2 Diabetes Mellitus: Screening Tool or Diagnostic Alternative? — Ernawati Ernawati · Journal of Applied Data Sciences (2026) | TGRS Research Map | TGRS