On the Origin of “Picket Fence” Peaks: Spectral Complexity, Mass Defect Uniformity, and Mass-to-Charge Ratio Alignment in Tandem Mass Spectra of Intact Proteins

Abstract Spectra from tandem mass spectrometry (MS/MS) of intact proteins are often highly complex, containing numerous closely spaced peaks arising from fragment ions with similar m/z values. This high level of spectral density continues to challenge even state-of-the-art high-resolution mass spectrometers, particularly as protein size increases. Here, we show that this complexity can produce a misleading spectral interference pattern when dissociating proteins whose fragment ions exhibit a sufficiently linear relationship between fragment mass and mass defect. In such cases, isotopic m/z peaks from multiple fragment ions constructively overlap to produce a series of predominantly ∼1 m/z-spaced peaks, which we refer to as a “picket-fence” pattern. These peaks are easily misinterpreted as signals from much lower mass fragment ions (“peak at every mass” background) or distort expected isotopic peak envelopes. More fundamentally, these picket fence peaks can be understood as the collective manifestation of a high spectral density of signals arising from both sequence ions and the aggregate contribution of numerous individually low-abundance internal fragment ions. Recognizing and accounting for this often-observed phenomenon is essential for accurate fragment-ion assignment and interpretation of intact protein MS/MS spectra.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-10-28
DOI
https://doi.org/10.1021/jasms.6c00257
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.53

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Origin of “Picket Fence” Peaks: Spectral Complexity, Mass Defect Uniformity, and Mass-to-Charge Ratio Alignment in Tandem Mass Spectra of Intact Proteins

John E. P. Syka, Donald F. Hunt, Jeffrey Shabanowitz, Joshua D. Hinkle et al.
1 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
1.53
article

On the Origin of “Picket Fence” Peaks: Spectral Complexity, Mass Defect Uniformity, and Mass-to-Charge Ratio Alignment in Tandem Mass Spectra of Intact Proteins

John E. P. Syka, Donald F. Hunt, Jeffrey Shabanowitz, Joshua D. Hinkle, Lissa C. Anderson, Romain Huguet, Greg T. Blakney, Steven Alexander DeFiglia, Robert A. D’Ippolito, Håkan Håkansson, Ping F. Yip, Christopher Mullen
article en
1 citations

Abstract

Abstract Spectra from tandem mass spectrometry (MS/MS) of intact proteins are often highly complex, containing numerous closely spaced peaks arising from fragment ions with similar m/z values. This high level of spectral density continues to challenge even state-of-the-art high-resolution mass spectrometers, particularly as protein size increases. Here, we show that this complexity can produce a misleading spectral interference pattern when dissociating proteins whose fragment ions exhibit a sufficiently linear relationship between fragment mass and mass defect. In such cases, isotopic m/z peaks from multiple fragment ions constructively overlap to produce a series of predominantly ∼1 m/z-spaced peaks, which we refer to as a “picket-fence” pattern. These peaks are easily misinterpreted as signals from much lower mass fragment ions (“peak at every mass” background) or distort expected isotopic peak envelopes. More fundamentally, these picket fence peaks can be understood as the collective manifestation of a high spectral density of signals arising from both sequence ions and the aggregate contribution of numerous individually low-abundance internal fragment ions. Recognizing and accounting for this often-observed phenomenon is essential for accurate fragment-ion assignment and interpretation of intact protein MS/MS spectra.

Journal of the American Society for Mass Spectrometry
Florida State University (US), National High Magnetic Field Laboratory (US), Thermo Fisher Scientific (United States) (US), University of Virginia (US)
National Institute of General Medical Sciences, Division of Chemistry
Openalex Percentile: Top 13%
Mass Spectrometry Techniques and Applications
1.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon