Self-interpreting quasi-site-rich electroanalytical interface for autonomous biosensing of hepatotoxic drugs

. This metal-free interface enables sensitive and selective detection of acetaminophen (APAP) and diclofenac (DCF) drug molecules, even at low abundance (LOD's: 0.89 ± 0.04 nM, 4.61 ± 0.32 nM), exhibiting strong selectivity against physiological interferents (<10% deviation) and stable analytical performance in PBS and human serum (∼97% signal retention) with excellent serum recovery (∼98%), demonstrating its potential for on-site monitoring. The engineered interface is experimentally calibrated for practical purposes and digitally integrated with a smartphone-deployable application, HepatoAI, enabling rapid interpretation of electrochemical signals into actionable therapeutic decisions. This work demonstrates that engineered carbon microinterfaces can be seamlessly integrated into intelligent fiber-based devices and electronics for autonomous human healthcare monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2026-11-18
DOI
https://doi.org/10.1039/d6tb01454b
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Self-interpreting quasi-site-rich electroanalytical interface for autonomous biosensing of hepatotoxic drugs

Govindhan Maduraiveeran, Mohamed Hefayathullah
3 links
Journal of Materials Chemistry B
Electrochemical sensors and biosensors
article

Self-interpreting quasi-site-rich electroanalytical interface for autonomous biosensing of hepatotoxic drugs

Govindhan Maduraiveeran, Mohamed Hefayathullah
article en

Abstract

. This metal-free interface enables sensitive and selective detection of acetaminophen (APAP) and diclofenac (DCF) drug molecules, even at low abundance (LOD's: 0.89 ± 0.04 nM, 4.61 ± 0.32 nM), exhibiting strong selectivity against physiological interferents (<10% deviation) and stable analytical performance in PBS and human serum (∼97% signal retention) with excellent serum recovery (∼98%), demonstrating its potential for on-site monitoring. The engineered interface is experimentally calibrated for practical purposes and digitally integrated with a smartphone-deployable application, HepatoAI, enabling rapid interpretation of electrochemical signals into actionable therapeutic decisions. This work demonstrates that engineered carbon microinterfaces can be seamlessly integrated into intelligent fiber-based devices and electronics for autonomous human healthcare monitoring.

Journal of Materials Chemistry BVol. 14(44)
SRM Institute of Science and Technology (IN), American University of Sharjah (AE)
SRM Institute of Science and Technology
Good health and well-being
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon