Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing

Volar lunate facet (VLF) fractures are prone to loss of reduction after volar plating. We used finite element analysis (FEA) and cadaveric testing to identify failure mechanisms and determine how screw configuration alters load transfer. A CT-derived radius model with a 10 × 15 × 5-mm VLF fragment was fixed with a 4-hole hook plate using locking and nonlocking (NL) screws. A 500-N radiolunate compressive load was applied, and von Mises stresses were quantified. Sensitivity analyses varied loading, bone density, fracture characteristics, and implant material. Ten distal radii underwent cyclic loading followed by load-to-failure testing; failure modes and locations were compared with FEA hotspots. FEA identified two stress concentrations: the distal plate contour/screw-hole region and the ulnar hook insertion into the VLF fragment. In the baseline 1[NL]&3[NL] construct, peak construct and radius stresses were 697.2 and 154.6 MPa. The 1[NL]&2[NL] configuration produced the lowest stresses (54.5 and 27.3 MPa), whereas locking hole 3 reduced construct stress to 587.2 MPa. Cadaver failure load was 1239.2 ± 438.5 N (range: 630.0-1990.1 N); failures were loss of reduction/fracture dislocation (4/10) or plate failure (6/10), with failure locations corresponding to FEA hotspots. Off-axis loading, reduced bone density, and fracture-line translation increased construct stress and altered hotspot location. FEA-predicted hook-fragment stress corresponded to loss of reduction, whereas distal plate stress corresponded to plate failure. Among modeled configurations, 1[NL]&2[NL] minimized construct and radius stress, although unbalanced cadaveric groups preclude claims of clinical superiority. These findings support fragment capture while minimizing distal plate stress.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-10-28
DOI
https://doi.org/10.1002/jor.70305
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing

Alireza Gholipour, Jonathan Lans, Abhiram R. Bhashyam, Augustus D. Mazzocca et al.
1 links
Journal of Orthopaedic Research®
Orthopedic Surgery and Rehabilitation
article

Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing

Alireza Gholipour, Jonathan Lans, Abhiram R. Bhashyam, Augustus D. Mazzocca, Marco Tulio Di Stefano, Alyssa Lee
article en

Abstract

Volar lunate facet (VLF) fractures are prone to loss of reduction after volar plating. We used finite element analysis (FEA) and cadaveric testing to identify failure mechanisms and determine how screw configuration alters load transfer. A CT-derived radius model with a 10 × 15 × 5-mm VLF fragment was fixed with a 4-hole hook plate using locking and nonlocking (NL) screws. A 500-N radiolunate compressive load was applied, and von Mises stresses were quantified. Sensitivity analyses varied loading, bone density, fracture characteristics, and implant material. Ten distal radii underwent cyclic loading followed by load-to-failure testing; failure modes and locations were compared with FEA hotspots. FEA identified two stress concentrations: the distal plate contour/screw-hole region and the ulnar hook insertion into the VLF fragment. In the baseline 1[NL]&3[NL] construct, peak construct and radius stresses were 697.2 and 154.6 MPa. The 1[NL]&2[NL] configuration produced the lowest stresses (54.5 and 27.3 MPa), whereas locking hole 3 reduced construct stress to 587.2 MPa. Cadaver failure load was 1239.2 ± 438.5 N (range: 630.0-1990.1 N); failures were loss of reduction/fracture dislocation (4/10) or plate failure (6/10), with failure locations corresponding to FEA hotspots. Off-axis loading, reduced bone density, and fracture-line translation increased construct stress and altered hotspot location. FEA-predicted hook-fragment stress corresponded to loss of reduction, whereas distal plate stress corresponded to plate failure. Among modeled configurations, 1[NL]&2[NL] minimized construct and radius stress, although unbalanced cadaveric groups preclude claims of clinical superiority. These findings support fragment capture while minimizing distal plate stress.

Journal of Orthopaedic Research®Vol. 44(11)
Harvard University (US), Emory University (US), Massachusetts General Hospital (US)
Good health and well-being
Openalex Percentile: Top 10%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon