Limited anti-biofouling effect of surface-patterned membranes in spacer-filled feed channels over longer time periods

Topographical membrane surface patterns are a promising approach for increasing transmembrane flux and reducing foulant deposition. In this study, we investigated the anti-biofouling propensity of TFC membranes with micrometer-scale patterns. Unlike most studies in literature, where biofouling of patterned membranes was investigated without feed spacers and in short-term tests, we considered a) spacer-filled channels and b) advanced biofouling stages. We thereby addressed an important knowledge gap regarding the interaction between membrane surface patterns, spacer geometry, and biofouling dynamics. We found no substantial differences between surface-patterned and reference flat membranes regarding anti-fouling propensity in biofilm growth and membrane cleaning. Differences were marginal to modest ( < 10 % ) for most and not significant for all assessment methods (feed channel pressure drop, active/total biomass in final biofilms, and camera image data). To explain these findings, we suggest that the anti-fouling effects of micrometer-scale membrane surface patterns may be a) overridden by millimeter-scale feed spacers that dominate flow characteristics and biofouling dynamics and b) ultimately hindered by biofilm coverage in advanced biofouling stages. Besides, image-based fouling monitoring of advanced biofouling stages was critically assessed. Although no substantial differences between flat and surface-patterned membranes were observed for the geometries (micrometer-scale line-and-groove patterns and millimeter-scale conventional spacers) and conditions (accelerated biofouling tests without permeation) tested, anti-fouling effects of patterned membranes in spacer-filled channels may occur under alternative operating conditions and geometry scales. We therefore recommend further biofouling tests, incorporating permeation, real desalination feed waters, adapted cleaning procedures, different pattern scales, and novel feed spacer geometries.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2026-10-28
DOI
https://doi.org/10.1016/j.jwpe.2026.111170
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limited anti-biofouling effect of surface-patterned membranes in spacer-filled feed channels over longer time periods

J.E. Drewes, A. Mitranescu, A. Khan, M. Patel et al.
1 links
Journal of Water Process Engineering
Membrane Separation Technologies
article

Limited anti-biofouling effect of surface-patterned membranes in spacer-filled feed channels over longer time periods

J.E. Drewes, A. Mitranescu, A. Khan, M. Patel, I.M.A. ElSherbiny, S. Panglisch, B.M. Aumeier
article en

Abstract

Topographical membrane surface patterns are a promising approach for increasing transmembrane flux and reducing foulant deposition. In this study, we investigated the anti-biofouling propensity of TFC membranes with micrometer-scale patterns. Unlike most studies in literature, where biofouling of patterned membranes was investigated without feed spacers and in short-term tests, we considered a) spacer-filled channels and b) advanced biofouling stages. We thereby addressed an important knowledge gap regarding the interaction between membrane surface patterns, spacer geometry, and biofouling dynamics. We found no substantial differences between surface-patterned and reference flat membranes regarding anti-fouling propensity in biofilm growth and membrane cleaning. Differences were marginal to modest ( < 10 % ) for most and not significant for all assessment methods (feed channel pressure drop, active/total biomass in final biofilms, and camera image data). To explain these findings, we suggest that the anti-fouling effects of micrometer-scale membrane surface patterns may be a) overridden by millimeter-scale feed spacers that dominate flow characteristics and biofouling dynamics and b) ultimately hindered by biofilm coverage in advanced biofouling stages. Besides, image-based fouling monitoring of advanced biofouling stages was critically assessed. Although no substantial differences between flat and surface-patterned membranes were observed for the geometries (micrometer-scale line-and-groove patterns and millimeter-scale conventional spacers) and conditions (accelerated biofouling tests without permeation) tested, anti-fouling effects of patterned membranes in spacer-filled channels may occur under alternative operating conditions and geometry scales. We therefore recommend further biofouling tests, incorporating permeation, real desalination feed waters, adapted cleaning procedures, different pattern scales, and novel feed spacer geometries.

Journal of Water Process EngineeringVol. 93
University of Duisburg-Essen (DE), Technical University of Munich (DE)
Deutsche Forschungsgemeinschaft
Clean water and sanitation
Openalex Percentile: Top 25%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon