Method of operational control of antimony content in metallurgical samples of copper production

The optimal conditions for the preliminary chemical preparation of copper production metallurgical samples were found and the uncertainty of antimony determination by inductively coupled plasma atomic emission spectrometry in solutions obtained after sample digestion by sintering was assessed. Three copper production metallurgical samples with varying analyte concentrations — copper concentrate, metallurgical slag, and copper production dust — were used for the study. Sample preparation was performed by sintering with a mixture of sodium carbonate and zinc oxide, and the optimal digestion process parameters were established using a probabilistic-deterministic four-factor experimental design method at six levels. For copper concentrate and metallurgical slag samples, a significant influence of all four factors studied on the degree of antimony extraction from the solid phase into solution was established. For the copper production dust sample, the influence of only two factors — sample weight and the proportion of reagent in the mixture — was significant. It was found that the maximum degree of antimony extraction from the solid phase into solution is achieved with a sample weight of 0.1 g, a sintering temperature of 900°C, a reagent mass fraction in the sintering mixture of 75%, and a sintering time of 60 min. Based on the obtained results, a technique of antimony determination by ICP-AES in solutions obtained after sintering metallurgical samples was developed. The expanded uncertainty value was estimated for three test samples with different analyte concentrations: 0.044 ± 0.001 wt.%, 0.085 ± 0.012 wt.%, and 0.25 ± 0.08 wt.% The developed technique involves the determination of antimony content using ICP-AES in three analyte concentration ranges: 0.010 – 0.050, 0.050 – 0.10, and 0.10 – 0.30 wt.% The proposed method can be used in industrial laboratories for antimony content monitoring in various metallurgical samples of copper production.

Authors

Institutions

Publication Details

Journal
Industrial laboratory Diagnostics of materials
Published
2026-10-27
DOI
https://doi.org/10.26896/1028-6861-2026-92-10-32-41
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method of operational control of antimony content in metallurgical samples of copper production

Жилкашинова Альмира Михайловна, S. K. Kabdrahmanova, A. V. Troyeglazova
Industrial laboratory Diagnostics of materials
Analytical chemistry methods development
article

Method of operational control of antimony content in metallurgical samples of copper production

Жилкашинова Альмира Михайловна, S. K. Kabdrahmanova, A. V. Troyeglazova
article en

Abstract

The optimal conditions for the preliminary chemical preparation of copper production metallurgical samples were found and the uncertainty of antimony determination by inductively coupled plasma atomic emission spectrometry in solutions obtained after sample digestion by sintering was assessed. Three copper production metallurgical samples with varying analyte concentrations — copper concentrate, metallurgical slag, and copper production dust — were used for the study. Sample preparation was performed by sintering with a mixture of sodium carbonate and zinc oxide, and the optimal digestion process parameters were established using a probabilistic-deterministic four-factor experimental design method at six levels. For copper concentrate and metallurgical slag samples, a significant influence of all four factors studied on the degree of antimony extraction from the solid phase into solution was established. For the copper production dust sample, the influence of only two factors — sample weight and the proportion of reagent in the mixture — was significant. It was found that the maximum degree of antimony extraction from the solid phase into solution is achieved with a sample weight of 0.1 g, a sintering temperature of 900°C, a reagent mass fraction in the sintering mixture of 75%, and a sintering time of 60 min. Based on the obtained results, a technique of antimony determination by ICP-AES in solutions obtained after sintering metallurgical samples was developed. The expanded uncertainty value was estimated for three test samples with different analyte concentrations: 0.044 ± 0.001 wt.%, 0.085 ± 0.012 wt.%, and 0.25 ± 0.08 wt.% The developed technique involves the determination of antimony content using ICP-AES in three analyte concentration ranges: 0.010 – 0.050, 0.050 – 0.10, and 0.10 – 0.30 wt.% The proposed method can be used in industrial laboratories for antimony content monitoring in various metallurgical samples of copper production.

Industrial laboratory Diagnostics of materialsVol. 92(10)
Satbayev University (KZ), Sarsen Amanzholov East Kazakhstan University (KZ), Siberian State University Geosystems and Technology (RU)
Openalex Percentile: Top 19%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon