In-sheath forceps‑to‑snare exchange during laser-assisted retrieval of a fractured OptEase inferior vena cava filter: a technical note

The pivotal role of bidirectional pulling with forceps, snare or both for removal of long-dwelling biconical vena cava filters is largely recognized. We describe an in-sheath transition from rigid laparoscopic forceps to a snare during a dual access laser-assisted retrieval of an embedded, fractured OptEase ® filter (Cordis). In 2022, a 79-year-old woman received the filter for iliofemoral deep vein thrombosis with contraindication to anticoagulation. After an unsuccessful attempt elsewhere, imaging at a 1360-day dwell time showed rightward tilting, severe embedding of both apices, transmural penetration and a fractured cranial strut. Under general anesthesia, laparoscopic forceps introduced through 22 F jugular and femoral sheaths established bidirectional traction, but to-and-fro manoeuvres failed to free the filter, requiring laser assistance. As the forceps could not fit the 16 F laser sheath, the 22 F femoral sheath was advanced to collapse the caudal apex within its lumen and the forceps were removed, leaving the apex coaxially constrained. An Amplatz Goose Neck ® snare pre-loaded within a 16 F GlideLight ® laser sheath easily recaptured the apex. With bidirectional traction restored, circumferential laser pulses ablated the neointimal tissue, and the filter was retrieved from below. Completion venography and cone-beam CT documented a retained 1-cm strut fragment and a clinically silent focal caval pseudoaneurysm, managed with balloon tamponade alone. She remained hemodynamically stable without transfusion and was discharged after three days on low-molecular-weight heparin; four-week CT showed resorption. To our knowledge, this in-sheath transition has not been described among the techniques adjunctive to filter ensheathment. It may be a useful option for long-dwelling biconical filters when advanced techniques with laparoscopic graspers have failed, overcoming device-sheath incompatibility and preserving bidirectional traction during laser-assisted dissection.

Authors

Institutions

Publication Details

Journal
Journal of Medical Imaging and Interventional Radiology
Published
2026-10-28
DOI
https://doi.org/10.1007/s44326-026-00130-0
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-sheath forceps‑to‑snare exchange during laser-assisted retrieval of a fractured OptEase inferior vena cava filter: a technical note

Antonio Bozzani, Ludovico Ambrosi, Pietro Quaretti, Nicola Cionfoli et al.
Journal of Medical Imaging and Interventional Radiology
Central Venous Catheters and Hemodialysis
article

In-sheath forceps‑to‑snare exchange during laser-assisted retrieval of a fractured OptEase inferior vena cava filter: a technical note

Antonio Bozzani, Ludovico Ambrosi, Pietro Quaretti, Nicola Cionfoli, Riccardo Corti, Antonio D’Agostino, Gabriele Rosolen
article en

Abstract

The pivotal role of bidirectional pulling with forceps, snare or both for removal of long-dwelling biconical vena cava filters is largely recognized. We describe an in-sheath transition from rigid laparoscopic forceps to a snare during a dual access laser-assisted retrieval of an embedded, fractured OptEase ® filter (Cordis). In 2022, a 79-year-old woman received the filter for iliofemoral deep vein thrombosis with contraindication to anticoagulation. After an unsuccessful attempt elsewhere, imaging at a 1360-day dwell time showed rightward tilting, severe embedding of both apices, transmural penetration and a fractured cranial strut. Under general anesthesia, laparoscopic forceps introduced through 22 F jugular and femoral sheaths established bidirectional traction, but to-and-fro manoeuvres failed to free the filter, requiring laser assistance. As the forceps could not fit the 16 F laser sheath, the 22 F femoral sheath was advanced to collapse the caudal apex within its lumen and the forceps were removed, leaving the apex coaxially constrained. An Amplatz Goose Neck ® snare pre-loaded within a 16 F GlideLight ® laser sheath easily recaptured the apex. With bidirectional traction restored, circumferential laser pulses ablated the neointimal tissue, and the filter was retrieved from below. Completion venography and cone-beam CT documented a retained 1-cm strut fragment and a clinically silent focal caval pseudoaneurysm, managed with balloon tamponade alone. She remained hemodynamically stable without transfusion and was discharged after three days on low-molecular-weight heparin; four-week CT showed resorption. To our knowledge, this in-sheath transition has not been described among the techniques adjunctive to filter ensheathment. It may be a useful option for long-dwelling biconical filters when advanced techniques with laparoscopic graspers have failed, overcoming device-sheath incompatibility and preserving bidirectional traction during laser-assisted dissection.

Journal of Medical Imaging and Interventional Radiology
University of Pavia (IT), Policlinico San Matteo Fondazione (IT)
Good health and well-being
Openalex Percentile: Top 8%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon