Spatial engineering of nanocomposite microneedle arrays for interstitial fluid sampling, detection, and stable readout

Nanocomposite microneedle arrays are promising platforms for minimally invasive interstitial fluid (ISF) monitoring, integrating skin-accessible microscale structures with functional nanomaterials. Nevertheless, inefficient microsample utilization, limited target enrichment, unstable signal transduction, wet-state mechanical failure, biofouling, and long-term readout drift continue to limit reliable ISF monitoring. These problems are determined not only by the choice of nanomaterials, but also by the fact whether functional components are located in places corresponding to bottlenecks at the device level. In this Review, we employ a spatial engineering method to evaluate nanocomposite microneedle arrays and categorise representative strategies into three groups: bulk incorporation, surface functionalization, and channel functionalization. We explore the significance of these spatial arrangements for three related functional aspects: sampling, detection, and readout stability. Matrix strength, swelling and microsample retention are primarily governed by bulk incorporation. Recognition and transduction interfaces are reconstructed by surface functionalization while sample transport, local enrichment and continuous supply to sensor regions are controlled by channel functionalization. We discuss design trade-offs concerning mechanical reinforcement versus mass transfer, signal amplification versus stability, and antifouling protection versus diffusion resistance, and translational criteria including biosafety, batch consistency, storage stability and scalable manufacturing. This spatially resolved approach could enable the rational design of reliable nanocomposite microneedle systems for ISF-based biochemical monitoring.

Authors

Institutions

Publication Details

Journal
Materials Today Advances
Published
2026-10-27
DOI
https://doi.org/10.1016/j.mtadv.2026.101032
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial engineering of nanocomposite microneedle arrays for interstitial fluid sampling, detection, and stable readout

Teng Zhang, Zhe Chen, Tian Mao, Dan Zhang et al.
2 links
Materials Today Advances
Advancements in Transdermal Drug Delivery
article

Spatial engineering of nanocomposite microneedle arrays for interstitial fluid sampling, detection, and stable readout

Teng Zhang, Zhe Chen, Tian Mao, Dan Zhang, Jinpeng Ji, Yi Wang, Lei Tong
article en

Abstract

Nanocomposite microneedle arrays are promising platforms for minimally invasive interstitial fluid (ISF) monitoring, integrating skin-accessible microscale structures with functional nanomaterials. Nevertheless, inefficient microsample utilization, limited target enrichment, unstable signal transduction, wet-state mechanical failure, biofouling, and long-term readout drift continue to limit reliable ISF monitoring. These problems are determined not only by the choice of nanomaterials, but also by the fact whether functional components are located in places corresponding to bottlenecks at the device level. In this Review, we employ a spatial engineering method to evaluate nanocomposite microneedle arrays and categorise representative strategies into three groups: bulk incorporation, surface functionalization, and channel functionalization. We explore the significance of these spatial arrangements for three related functional aspects: sampling, detection, and readout stability. Matrix strength, swelling and microsample retention are primarily governed by bulk incorporation. Recognition and transduction interfaces are reconstructed by surface functionalization while sample transport, local enrichment and continuous supply to sensor regions are controlled by channel functionalization. We discuss design trade-offs concerning mechanical reinforcement versus mass transfer, signal amplification versus stability, and antifouling protection versus diffusion resistance, and translational criteria including biosafety, batch consistency, storage stability and scalable manufacturing. This spatially resolved approach could enable the rational design of reliable nanocomposite microneedle systems for ISF-based biochemical monitoring.

Materials Today AdvancesVol. 32
Shanxi Medical University (CN), China Institute for Radiation Protection (CN)
Openalex Percentile: Top 15%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon