Tomographic ultrasound (tUS) for thyroid volume determination

BACKGROUND: Accurate thyroid volume determination is essential for treatment planning. This feasibility study evaluated the accuracy of a novel tomographic ultrasound (tUS) approach compared to 2D ultrasound, using contrast-enhanced computed tomography (ceCT) as reference standard. METHODS: In this prospective, single-center study, 50 patients undergoing neck ceCT were enrolled. Thyroid volume was measured by 2D ultrasound (ellipsoid model), automatedvolume (tUS uncorrected), physician-corrected volume (tUS corrected) and ceCT. Linear regression for proportional bias, log-transformed Bland-Altman analysis, clinical error metrics and correction duration were evaluated. RESULTS: 2D ultrasound showed significant proportional bias (slope=-0.215, p<0.0001) and systematic underestimation (mean difference -6.0mL; geometric mean ratio 0.76). Corrected tUS eliminated proportional bias (p=0.0557) and reduced bias (mean difference +0.8mL; geometric mean ratio 1.04). Corrected tUS achieved lower MAE (4.42mL vs. 6.53mL) and MAPE (19.4% vs. 25.4%) than 2D ultrasound, placing 60.0% vs. 34.0% of cases within ±20% error limits. In enlarged glands (n=19), corrected tUS maintained superior accuracy (MAE 5.82mL, MAPE 12.4%) versus 2D ultrasound (MAE 11.35mL, MAPE 26.5%). Physician correction averaged 2:51minutes, independent of thyroid volume (r=-0.081, p=0.5784). CONCLUSIONS: In this feasibility study, physician-corrected tUS reduced the size-dependent systematic underestimation observed with 2D ultrasound and yielded volumes closer to ceCT, particularly in enlarged glands, within a clinically feasible workflow. Because the best-performing method required manual expert correction and the limits of agreement with ceCT exceeded the predefined clinical threshold, corrected tUS should be regarded as a promising semi-automated approach that requires further validation, including interobserver assessment, before it can be considered interchangeable with ceCT.

Authors

Institutions

Publication Details

Journal
The Ultrasound Journal
Published
2026-10-27
DOI
https://doi.org/10.5826/tuj.2026.19437
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tomographic ultrasound (tUS) for thyroid volume determination

Martin G. Freesmeyer, Falk Gühne, Philipp Seifert, Christian Kühnel et al.
1 links
The Ultrasound Journal
Ultrasound in Clinical Applications
article

Tomographic ultrasound (tUS) for thyroid volume determination

Martin G. Freesmeyer, Falk Gühne, Philipp Seifert, Christian Kühnel, Michael Pöhlmann
article en

Abstract

BACKGROUND: Accurate thyroid volume determination is essential for treatment planning. This feasibility study evaluated the accuracy of a novel tomographic ultrasound (tUS) approach compared to 2D ultrasound, using contrast-enhanced computed tomography (ceCT) as reference standard. METHODS: In this prospective, single-center study, 50 patients undergoing neck ceCT were enrolled. Thyroid volume was measured by 2D ultrasound (ellipsoid model), automatedvolume (tUS uncorrected), physician-corrected volume (tUS corrected) and ceCT. Linear regression for proportional bias, log-transformed Bland-Altman analysis, clinical error metrics and correction duration were evaluated. RESULTS: 2D ultrasound showed significant proportional bias (slope=-0.215, p<0.0001) and systematic underestimation (mean difference -6.0mL; geometric mean ratio 0.76). Corrected tUS eliminated proportional bias (p=0.0557) and reduced bias (mean difference +0.8mL; geometric mean ratio 1.04). Corrected tUS achieved lower MAE (4.42mL vs. 6.53mL) and MAPE (19.4% vs. 25.4%) than 2D ultrasound, placing 60.0% vs. 34.0% of cases within ±20% error limits. In enlarged glands (n=19), corrected tUS maintained superior accuracy (MAE 5.82mL, MAPE 12.4%) versus 2D ultrasound (MAE 11.35mL, MAPE 26.5%). Physician correction averaged 2:51minutes, independent of thyroid volume (r=-0.081, p=0.5784). CONCLUSIONS: In this feasibility study, physician-corrected tUS reduced the size-dependent systematic underestimation observed with 2D ultrasound and yielded volumes closer to ceCT, particularly in enlarged glands, within a clinically feasible workflow. Because the best-performing method required manual expert correction and the limits of agreement with ceCT exceeded the predefined clinical threshold, corrected tUS should be regarded as a promising semi-automated approach that requires further validation, including interobserver assessment, before it can be considered interchangeable with ceCT.

The Ultrasound JournalVol. 18(1)
Jena University Hospital (DE)
Good health and well-being
Openalex Percentile: Top 11%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon