Impact of Font Style on Reading Parameters: Comparing Radner Reading Charts Printed in Times New Roman and Arial

PURPOSE: To compare the effect of font type on reading parameters by using the ISO7921:2024 compliant RADNER Reading Charts printed in two fonts: Times New Roman PS (serif) and Arial MS (sans-serif). METHODS: A prospective cross-sectional study was conducted with 63 participants (native German speakers; mean age: 42.40 ± 14.65 years). Reading performance was evaluated binocularly with International Standards Organization (ISO) 7921:2024 compliant RADNER Reading Charts printed in Times New Roman PS and Arial MS. Print sizes were equalised in terms of x-heights. The reading charts were presented in random order at a test distance of 40 cm. Three reading acuity (RA) parameters were investigated: RA, reading acuity score (RAS) and critical print size (CPS); as well as three reading speed parameters: mean reading speed for all sentences (MEAN-ALL RS), mean reading speed within the range of 0.8-0.3 logRAD (MEAN-RS) and maximum reading speed (MAX-RS). RESULTS: No statistically significant differences were found between Times New Roman PS and Arial MS for any of the three reading acuity-related parameters (RA, RAS and CPS) or any of the three reading speed-related parameters (MEAN-ALL RS, MEAN-RS and MAX-RS) (all p > 0.07 for acuity-related parameters, and all p > 0.40 for reading speed-related parameters). The differences in all reading parameters were small, with narrow confidence intervals. There were strong correlations between the two fonts, with correlation coefficients ranging from r = 0.76 to 0.89. CONCLUSION: When equalised for x-height and layout, the comparable reading performance observed with Times New Roman PS and Arial MS suggests that these fonts can be used interchangeably for reading charts standardised in accordance with ISO 7921:2024.

Authors

Institutions

Publication Details

Journal
Ophthalmic and Physiological Optics
Published
2026-10-27
DOI
https://doi.org/10.1007/s44402-026-00199-w
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Font Style on Reading Parameters: Comparing Radner Reading Charts Printed in Times New Roman and Arial

Wolfgang Radner, Michael Radner, Thomas Benesch, Vinzenz Rudnay et al.
Ophthalmic and Physiological Optics
Ophthalmology and Visual Impairment Studies
article

Impact of Font Style on Reading Parameters: Comparing Radner Reading Charts Printed in Times New Roman and Arial

Wolfgang Radner, Michael Radner, Thomas Benesch, Vinzenz Rudnay, Ettl Armin, Maximilian Breschan
article en

Abstract

PURPOSE: To compare the effect of font type on reading parameters by using the ISO7921:2024 compliant RADNER Reading Charts printed in two fonts: Times New Roman PS (serif) and Arial MS (sans-serif). METHODS: A prospective cross-sectional study was conducted with 63 participants (native German speakers; mean age: 42.40 ± 14.65 years). Reading performance was evaluated binocularly with International Standards Organization (ISO) 7921:2024 compliant RADNER Reading Charts printed in Times New Roman PS and Arial MS. Print sizes were equalised in terms of x-heights. The reading charts were presented in random order at a test distance of 40 cm. Three reading acuity (RA) parameters were investigated: RA, reading acuity score (RAS) and critical print size (CPS); as well as three reading speed parameters: mean reading speed for all sentences (MEAN-ALL RS), mean reading speed within the range of 0.8-0.3 logRAD (MEAN-RS) and maximum reading speed (MAX-RS). RESULTS: No statistically significant differences were found between Times New Roman PS and Arial MS for any of the three reading acuity-related parameters (RA, RAS and CPS) or any of the three reading speed-related parameters (MEAN-ALL RS, MEAN-RS and MAX-RS) (all p > 0.07 for acuity-related parameters, and all p > 0.40 for reading speed-related parameters). The differences in all reading parameters were small, with narrow confidence intervals. There were strong correlations between the two fonts, with correlation coefficients ranging from r = 0.76 to 0.89. CONCLUSION: When equalised for x-height and layout, the comparable reading performance observed with Times New Roman PS and Arial MS suggests that these fonts can be used interchangeably for reading charts standardised in accordance with ISO 7921:2024.

Ophthalmic and Physiological Optics
Austrian Academy of Sciences (AT), Universitätsklinikum St. Pölten (AT), Karl Landsteiner University of Health Sciences (AT)
Openalex Percentile: Top 12%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon