Comparison of digital, semi-digital, and conventional fit evaluation methods for additively and subtractively manufactured zirconia three-unit fixed dental prostheses.

OBJECTIVES: To assess the fit of additively and subtractively manufactured zirconia fixed dental prostheses (FDPs) using different evaluation methods and compare alternative methods with the conventional method. METHODS: Three-unit FDPs were fabricated additively from zirconia slurry (AM) or subtractively from highly translucent (SM-HT) or strength-gradient zirconia (SM-SG) (n = 15 per group). Fit was assessed using digital (modified triple-scan), semi-digital (three-dimensional [3D] and two-dimensional [2D] silicone replica), and conventional silicone replica methods. Gap values were analyzed using a linear mixed-effects model and Bonferroni-corrected post hoc comparisons. Agreement and proportional bias between each alternative method and the conventional method were evaluated separately within each material using Bland-Altman and simple linear regression analyses, respectively (α = 0.05). RESULTS: Material, assessment method, and their interaction affected measured gaps (P < 0.001). AM FDPs showed greater gaps than subtractively manufactured FDPs with the 3D and conventional silicone replica methods, while the 3D method yielded the highest values within each material (P < 0.001). Bland-Altman analysis revealed material-dependent biases. Significant proportional bias was detected for modified triple-scan across all materials (negative, P < 0.001), 2D silicone replica in AM and SM-SG (negative, P ≤ 0.002), and 3D silicone replica only in SM-HT (positive, P = 0.001). CONCLUSIONS: Measured gap values and comparisons among tested FDPs depended on the assessment method. Group mean gap values exceeded the designed cement space. Intermethod biases varied by material and assessment method. CLINICAL SIGNIFICANCE: Under the conditions of this in vitro study, fit assessment method influenced measured gap values and comparisons among tested FDPs, with limited quantitative interchangeability between alternative and conventional methods. Combining marginal and internal adaptation into overall gap values limits clinical interpretation. Measured values do not establish clinical acceptability or long-term prosthetic success.

Authors

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-10-26
DOI
https://doi.org/10.48620/102017
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of digital, semi-digital, and conventional fit evaluation methods for additively and subtractively manufactured zirconia three-unit fixed dental prostheses.

Begüm Ünlü Kurşun, Çiğdem Kahveci, Mustafa Borga Dönmez, Eleni Trikoili et al.
Open Access CRIS of the University of Bern
Dental materials and restorations
article

Comparison of digital, semi-digital, and conventional fit evaluation methods for additively and subtractively manufactured zirconia three-unit fixed dental prostheses.

Begüm Ünlü Kurşun, Çiğdem Kahveci, Mustafa Borga Dönmez, Eleni Trikoili, Burak Yilmaz
article en

Abstract

OBJECTIVES: To assess the fit of additively and subtractively manufactured zirconia fixed dental prostheses (FDPs) using different evaluation methods and compare alternative methods with the conventional method. METHODS: Three-unit FDPs were fabricated additively from zirconia slurry (AM) or subtractively from highly translucent (SM-HT) or strength-gradient zirconia (SM-SG) (n = 15 per group). Fit was assessed using digital (modified triple-scan), semi-digital (three-dimensional [3D] and two-dimensional [2D] silicone replica), and conventional silicone replica methods. Gap values were analyzed using a linear mixed-effects model and Bonferroni-corrected post hoc comparisons. Agreement and proportional bias between each alternative method and the conventional method were evaluated separately within each material using Bland-Altman and simple linear regression analyses, respectively (α = 0.05). RESULTS: Material, assessment method, and their interaction affected measured gaps (P < 0.001). AM FDPs showed greater gaps than subtractively manufactured FDPs with the 3D and conventional silicone replica methods, while the 3D method yielded the highest values within each material (P < 0.001). Bland-Altman analysis revealed material-dependent biases. Significant proportional bias was detected for modified triple-scan across all materials (negative, P < 0.001), 2D silicone replica in AM and SM-SG (negative, P ≤ 0.002), and 3D silicone replica only in SM-HT (positive, P = 0.001). CONCLUSIONS: Measured gap values and comparisons among tested FDPs depended on the assessment method. Group mean gap values exceeded the designed cement space. Intermethod biases varied by material and assessment method. CLINICAL SIGNIFICANCE: Under the conditions of this in vitro study, fit assessment method influenced measured gap values and comparisons among tested FDPs, with limited quantitative interchangeability between alternative and conventional methods. Combining marginal and internal adaptation into overall gap values limits clinical interpretation. Measured values do not establish clinical acceptability or long-term prosthetic success.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 9%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon