Capture Verification in Left Bundle Branch Area Pacing: Reporting Gaps and a Practical Framework

BACKGROUND: Left bundle branch area pacing (LBBAP) comprises two physiologically distinct interventions: left bundle branch pacing (LBBP), which captures the conduction system, and left ventricular septal pacing (LVSP), which captures septal myocardium only. How consistently studies document which was achieved is unknown. METHODS: We searched PubMed/MEDLINE, Europe PMC, and OpenAlex to June 21, 2026, and audited the eligible studies against ten prespecified reporting items, four primary and six supporting. Screening and extraction were independent and in duplicate. A continuous 0-100 score, threshold sensitivity analyses, and stratification were post hoc. RESULTS: An explicit capture definition was reported in 43 of 46 studies (93%), a numerator with denominator in 32 (70%), and outcomes by capture status in 18 (39%). LBBP, LVSP, and indeterminate capture were separated in one study (2%). Independent adjudication was described in two (4%), follow-up reassessment in seven (15%), and programmed output in three (7%). No study reported all four primary items with at least four supporting items; the median score was 43.3. Across seven alternative thresholds, six studies (13%) qualified at most. Studies from 2024 to 2026 scored higher than those from 2020 to 2023 (median 55.0 vs. 36.7; p = 0.015), although reporting of adjudication did not improve and reporting of reassessment only marginally. These comparisons were exploratory and unadjusted for multiplicity. CONCLUSIONS: In LBBAP studies with extractable capture information, capture verification is reported inconsistently and is often not separated from procedural success. We propose a reporting framework and an exploratory, author-derived capture-confidence score.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-10-27
DOI
https://doi.org/10.1111/pace.70477
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capture Verification in Left Bundle Branch Area Pacing: Reporting Gaps and a Practical Framework

Κonstantinos P. Letsas, Ourania K. Kariki, Michael Efremidis, Paraskevas Tsaplaris et al.
2 links
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Capture Verification in Left Bundle Branch Area Pacing: Reporting Gaps and a Practical Framework

Κonstantinos P. Letsas, Ourania K. Kariki, Michael Efremidis, Paraskevas Tsaplaris, Athanasios Saplaouras, George Bazoukis, Stavroula Koskina, Panagiotis Mililis, Athanasios Makris, Sokratis Oikonomou
article en

Abstract

BACKGROUND: Left bundle branch area pacing (LBBAP) comprises two physiologically distinct interventions: left bundle branch pacing (LBBP), which captures the conduction system, and left ventricular septal pacing (LVSP), which captures septal myocardium only. How consistently studies document which was achieved is unknown. METHODS: We searched PubMed/MEDLINE, Europe PMC, and OpenAlex to June 21, 2026, and audited the eligible studies against ten prespecified reporting items, four primary and six supporting. Screening and extraction were independent and in duplicate. A continuous 0-100 score, threshold sensitivity analyses, and stratification were post hoc. RESULTS: An explicit capture definition was reported in 43 of 46 studies (93%), a numerator with denominator in 32 (70%), and outcomes by capture status in 18 (39%). LBBP, LVSP, and indeterminate capture were separated in one study (2%). Independent adjudication was described in two (4%), follow-up reassessment in seven (15%), and programmed output in three (7%). No study reported all four primary items with at least four supporting items; the median score was 43.3. Across seven alternative thresholds, six studies (13%) qualified at most. Studies from 2024 to 2026 scored higher than those from 2020 to 2023 (median 55.0 vs. 36.7; p = 0.015), although reporting of adjudication did not improve and reporting of reassessment only marginally. These comparisons were exploratory and unadjusted for multiplicity. CONCLUSIONS: In LBBAP studies with extractable capture information, capture verification is reported inconsistently and is often not separated from procedural success. We propose a reporting framework and an exploratory, author-derived capture-confidence score.

Pacing and Clinical Electrophysiology
Onassis Cardiac Surgery Center (GR)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon