Hardware in the Loop-Driven Parameter Identification for Wind Turbine Controllers Using a Hybrid WaOA-GMM Method

With the large-scale integration of renewable energy sources into power systems, the dynamic characteristics of renewable generators have a critical impact on grid security and stability. However, wind turbine manufacturers usually do not disclose key internal controller parameters, making it difficult for grid operators to establish accurate white-box models for assessing the electromagnetic transient (EMT) behavior of wind farms. To address this “black-box” challenge, this paper proposes a parameter identification framework driven by hardware-in-the-loop (HIL) simulation waveforms, combining the Walrus Optimization Algorithm (WaOA) and the Gaussian Mixture Model (GMM) to accurately identify the controller parameters of white-box wind turbine models. First, an HIL simulation platform was built, where the actual controller (or the manufacturer’s black-box model) is connected to a real-time simulator. By designing typical fault scenarios (e.g., voltage sags), high-fidelity response waveforms were recorded. Second, a generic white-box model covering both doubly fed induction generator (DFIG) and permanent magnet synchronous generator (PMSG) wind turbines was developed on the CloudPSS platform, and Sobol global sensitivity analysis was used to screen the dominant parameters that significantly influence transient responses. Third, a GMM was constructed to model the probabilistic relationship between the dominant parameters and the simulation errors, and the posterior parameter distribution was derived using conditional probability invariance. Finally, an improved WaOA was adopted to directly optimize the controller parameters; each walrus position represents a candidate parameter set, and in each iteration, the posterior distribution from the GMM guides the generation of “newborn walruses” (high-quality candidate parameter sets), greatly accelerating convergence and improving identification accuracy. An HIL case study on a PMSG-based direct-drive wind turbine demonstrates that the proposed method can accurately identify the white-box model parameters, achieving an active-power error below 5%, without relying on proprietary manufacturer information. The experimental validation in this work focuses on the PMSG configuration; the extension to DFIG-based wind turbines is identified as future work.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-10-26
DOI
https://doi.org/10.3390/en19215086
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hardware in the Loop-Driven Parameter Identification for Wind Turbine Controllers Using a Hybrid WaOA-GMM Method

Xuanren Meng, Zhiyuan Sun, Jinzhao Li, 胡弘 et al.
Energies
Wind Turbine Control Systems
article

Hardware in the Loop-Driven Parameter Identification for Wind Turbine Controllers Using a Hybrid WaOA-GMM Method

Xuanren Meng, Zhiyuan Sun, Jinzhao Li, 胡弘, Wenji Zhu, Xiaoming Wang
article en

Abstract

With the large-scale integration of renewable energy sources into power systems, the dynamic characteristics of renewable generators have a critical impact on grid security and stability. However, wind turbine manufacturers usually do not disclose key internal controller parameters, making it difficult for grid operators to establish accurate white-box models for assessing the electromagnetic transient (EMT) behavior of wind farms. To address this “black-box” challenge, this paper proposes a parameter identification framework driven by hardware-in-the-loop (HIL) simulation waveforms, combining the Walrus Optimization Algorithm (WaOA) and the Gaussian Mixture Model (GMM) to accurately identify the controller parameters of white-box wind turbine models. First, an HIL simulation platform was built, where the actual controller (or the manufacturer’s black-box model) is connected to a real-time simulator. By designing typical fault scenarios (e.g., voltage sags), high-fidelity response waveforms were recorded. Second, a generic white-box model covering both doubly fed induction generator (DFIG) and permanent magnet synchronous generator (PMSG) wind turbines was developed on the CloudPSS platform, and Sobol global sensitivity analysis was used to screen the dominant parameters that significantly influence transient responses. Third, a GMM was constructed to model the probabilistic relationship between the dominant parameters and the simulation errors, and the posterior parameter distribution was derived using conditional probability invariance. Finally, an improved WaOA was adopted to directly optimize the controller parameters; each walrus position represents a candidate parameter set, and in each iteration, the posterior distribution from the GMM guides the generation of “newborn walruses” (high-quality candidate parameter sets), greatly accelerating convergence and improving identification accuracy. An HIL case study on a PMSG-based direct-drive wind turbine demonstrates that the proposed method can accurately identify the white-box model parameters, achieving an active-power error below 5%, without relying on proprietary manufacturer information. The experimental validation in this work focuses on the PMSG configuration; the extension to DFIG-based wind turbines is identified as future work.

EnergiesVol. 19(21)
Wuhan University (CN)
Openalex Percentile: Top 23%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon