Calibration of Critical flow Venturi Nozzles in the transitional and turbulent boundary layer regime using hydrogen gas and air

Abstract Critical flow Venturi Nozzles (CFVNs) are expected to play a key role for metrology of gases in the future due to their affordability, reliability and flexibility. While their performance with several inert gases is well documented, there is a lack of experimental data when used with hydrogen. The objective of this work is to estimate the relevance of calibrating CFVNs with air as a surrogate gas for hydrogen, especially at transitional and turbulent flow regimes. Two nozzles with diameters 1 mm and 2 mm are calibrated with both hydrogen gas and air using a primary standard based on a pressure-Volume-Temperature-time (pVTt) system. The results show that the discharge coefficients of the CFVNs for hydrogen and air are within the expanded uncertainty of ±0.3 % (k=2) of the laboratory.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-10-27
DOI
https://doi.org/10.1088/1361-6501/aeba08
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of Critical flow Venturi Nozzles in the transitional and turbulent boundary layer regime using hydrogen gas and air

Rémy Maury, Maxime Mussard, Edvardas Venslovas, Hamidou SOUMARE
3 links
Measurement Science and Technology
Flow Measurement and Analysis
article

Calibration of Critical flow Venturi Nozzles in the transitional and turbulent boundary layer regime using hydrogen gas and air

Rémy Maury, Maxime Mussard, Edvardas Venslovas, Hamidou SOUMARE
article en

Abstract

Abstract Critical flow Venturi Nozzles (CFVNs) are expected to play a key role for metrology of gases in the future due to their affordability, reliability and flexibility. While their performance with several inert gases is well documented, there is a lack of experimental data when used with hydrogen. The objective of this work is to estimate the relevance of calibrating CFVNs with air as a surrogate gas for hydrogen, especially at transitional and turbulent flow regimes. Two nozzles with diameters 1 mm and 2 mm are calibrated with both hydrogen gas and air using a primary standard based on a pressure-Volume-Temperature-time (pVTt) system. The results show that the discharge coefficients of the CFVNs for hydrogen and air are within the expanded uncertainty of ±0.3 % (k=2) of the laboratory.

Measurement Science and Technology
Norwegian Metrology Service (NO), CESAME-EXADEBIT (France) (FR)
European Partnership on Metrology
Openalex Percentile: Top 23%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.