Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

Cardiovascular diseases remain the leading cause of mortality worldwide, driving the need for implantable technologies capable of repairing, supporting, replacing, and monitoring cardiovascular functions. Current cardiovascular technologies are commonly classified according to anatomical target or invasiveness, limiting direct comparison of how different systems interact with blood and tissues. We present a comparative review based on the distinction between intracardiovascular systems, directly exposed to blood flow, and extracardiovascular systems, primarily interacting with surrounding tissues. A total of 107 devices (77 actuation and 30 sensing technologies) across myocardial, vascular, and valvular domains were analyzed through a semiquantitative framework considering blood contact burden, biomimicry, invasiveness, bulkiness, softness, and clinical maturity. Our analysis reveals that clinically established actuation systems remain predominantly rigid and optimized for reliability and high hemodynamic support, whereas emerging soft technologies aim to improve mechanical compatibility with cardiovascular tissues and reduce physiological burden, although they largely remain preclinical. Blood‐contacting devices provide direct hemodynamic control but face major hemocompatibility constraints, while extracardiovascular approaches reduce blood exposure with more complex tissue coupling. Sensing technologies are generally less mature with the preference for minimally invasive monitoring whenever external acquisition is feasible. This review identifies interface‐dependent design trade‐offs and highlights key translational challenges toward adaptive, patient‐specific cardiovascular therapies.

Authors

Institutions

Publication Details

Journal
Advanced Intelligent Systems
Published
2026-10-27
DOI
https://doi.org/10.1002/aisy.70587
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

Matteo Cianchetti, Martina Maselli, Gastone Ciuti, Arianna Menciassi et al.
2 links
Advanced Intelligent Systems
Mechanical Circulatory Support Devices
article

Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

Matteo Cianchetti, Martina Maselli, Gastone Ciuti, Arianna Menciassi, Federica Semproni, Cesare Stefanini, Nicolò Bergo, Colli Andrea
article en

Abstract

Cardiovascular diseases remain the leading cause of mortality worldwide, driving the need for implantable technologies capable of repairing, supporting, replacing, and monitoring cardiovascular functions. Current cardiovascular technologies are commonly classified according to anatomical target or invasiveness, limiting direct comparison of how different systems interact with blood and tissues. We present a comparative review based on the distinction between intracardiovascular systems, directly exposed to blood flow, and extracardiovascular systems, primarily interacting with surrounding tissues. A total of 107 devices (77 actuation and 30 sensing technologies) across myocardial, vascular, and valvular domains were analyzed through a semiquantitative framework considering blood contact burden, biomimicry, invasiveness, bulkiness, softness, and clinical maturity. Our analysis reveals that clinically established actuation systems remain predominantly rigid and optimized for reliability and high hemodynamic support, whereas emerging soft technologies aim to improve mechanical compatibility with cardiovascular tissues and reduce physiological burden, although they largely remain preclinical. Blood‐contacting devices provide direct hemodynamic control but face major hemocompatibility constraints, while extracardiovascular approaches reduce blood exposure with more complex tissue coupling. Sensing technologies are generally less mature with the preference for minimally invasive monitoring whenever external acquisition is feasible. This review identifies interface‐dependent design trade‐offs and highlights key translational challenges toward adaptive, patient‐specific cardiovascular therapies.

Advanced Intelligent Systems
University of Pisa (IT), Scuola Superiore Sant'Anna (IT), Mohamed bin Zayed University of Artificial Intelligence (AE)
Good health and well-being
Openalex Percentile: Top 24%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon