Prevention and Management of Electrocautery-enhanced Lumen-apposing Metal Stent (EC-LAMS) Complications

Electrocautery-enhanced lumen apposing metal stents (EC-LAMS) have dramatically expanded the therapeutic capabilities of endoscopic ultrasound (EUS). Originally developed to make pseudocyst drainage more efficient, they are increasingly used to facilitate pancreatic necrosectomy, perform gallbladder and bile duct drainage, to create endoscopic gastroenterostomy, and as a conduit to the excluded stomach to facilitate endoscopic retrograde cholangiopancreatography (ERCP) in Roux en Y gastric bypass (RYGB) anatomy, among many other uses. In these settings, EC-LAMS offers substantial advantages to other available approaches. Yet, a major limitation to widespread adoption outside of high-volume referral centers is the high rate of adverse events (AEs) with EC-LAMS, which can occur in up to 1 in 5 patients. Misdeployment is a particularly dreaded complication; other common AEs include bleeding, peritoneal leak, stent occlusion, and stent migration. In this narrative review, we discuss risk factors associated with AEs for different EC-LAMS procedures and review general and procedure-specific measures to prevent complications. We also highlight techniques to successfully manage AEs.

Authors

Institutions

Publication Details

Journal
The American Journal of Gastroenterology
Published
2026-10-27
DOI
https://doi.org/10.14309/ajg.0000000000004237
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prevention and Management of Electrocautery-enhanced Lumen-apposing Metal Stent (EC-LAMS) Complications

Esli Medina‐Morales, Tilak Shah, Zaid Ansari, Judy A. Trieu
3 links
The American Journal of Gastroenterology
Gallbladder and Bile Duct Disorders
article

Prevention and Management of Electrocautery-enhanced Lumen-apposing Metal Stent (EC-LAMS) Complications

Esli Medina‐Morales, Tilak Shah, Zaid Ansari, Judy A. Trieu
article en

Abstract

Electrocautery-enhanced lumen apposing metal stents (EC-LAMS) have dramatically expanded the therapeutic capabilities of endoscopic ultrasound (EUS). Originally developed to make pseudocyst drainage more efficient, they are increasingly used to facilitate pancreatic necrosectomy, perform gallbladder and bile duct drainage, to create endoscopic gastroenterostomy, and as a conduit to the excluded stomach to facilitate endoscopic retrograde cholangiopancreatography (ERCP) in Roux en Y gastric bypass (RYGB) anatomy, among many other uses. In these settings, EC-LAMS offers substantial advantages to other available approaches. Yet, a major limitation to widespread adoption outside of high-volume referral centers is the high rate of adverse events (AEs) with EC-LAMS, which can occur in up to 1 in 5 patients. Misdeployment is a particularly dreaded complication; other common AEs include bleeding, peritoneal leak, stent occlusion, and stent migration. In this narrative review, we discuss risk factors associated with AEs for different EC-LAMS procedures and review general and procedure-specific measures to prevent complications. We also highlight techniques to successfully manage AEs.

The American Journal of Gastroenterology
University of North Carolina at Chapel Hill (US), Cleveland Clinic (US), Washington University in St. Louis (US), Cleveland Clinic Florida (US)
Good health and well-being
Openalex Percentile: Top 12%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Prevention and Management of Electrocautery-enhanced Lumen-apposing Metal Stent (EC-LAMS) Complications — Esli Medina‐Morales, Tilak Shah, et al. · The American Journal of Gastroenterology (2026) | TGRS Research Map | TGRS