Evaluation of Internal Quality Control Practices in a Blood Center Affiliated to a Tertiary Care Hospital: Compliance with WHO and NACO Standards

Background: Blood transfusion is indispensable in trauma, surgery, cancer therapy, and anemia management. Because transfusion carries the risk of infection and immune reaction, blood banks must maintain strict quality control (QC). Objective: To evaluate the quality control performance of a tertiary care blood bank and determine its compliance with World Health Organization (WHO) and National AIDS Control Organization (NACO) standards. Methods: A one-year observational study was performed at the Blood Bank, Sree Balaji Medical College and Hospital. Data were collected from donor screening, component preparation, infectious-disease testing, storage, equipment monitoring, and transfusion-reaction surveillance. QC was assessed according to NACO (GSR 166-E, 11-03-2020) domains: infrastructure, donor screening, post-phlebotomy, test processing, bag quality, bag thawing, and discard. Results: During the three - month study period, 250 donors were screened, of whom 5 (2%) were deferred based on NACO donor selection criteria. A total of 245 blood units were collected and processed into blood components. One hundred quality control (QC) samples comprising packed red blood cells (PRBCs), random donor platelets (RDPs), and fresh frozen plasma (FFP) were evaluated. Serological screening revealed HBsAg positivity of 2.3%, HCV positivity of 0.7%, syphilis positivity of 0.3%, and no HIV-reactive donations. Among the QC samples, 98% of PRBCs, RDPs, and FFPs complied with WHO/NACO quality standards. Storage temperatures remained within recommended limits, all equipment passed scheduled calibration, and only mild transfusion reactions (2%) were observed. Conclusion: Comprehensive QC practices in this blood bank achieved 97.5 percent compliance with WHO/NACO requirements. Effective infrastructure, donor screening, and component monitoring ensure high product quality and safe transfusion outcomes.

Authors

Publication Details

Journal
Asia Pacific Journal of Health Management
Published
2026-10-27
DOI
https://doi.org/10.24083/apjhm.v21i2.5751
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Internal Quality Control Practices in a Blood Center Affiliated to a Tertiary Care Hospital: Compliance with WHO and NACO Standards

Vinutha Gali, Thanka Johnson, Subhashini Paari, Dr. Afrin Fatima
4 links
Asia Pacific Journal of Health Management
Blood donation and transfusion practices
article

Evaluation of Internal Quality Control Practices in a Blood Center Affiliated to a Tertiary Care Hospital: Compliance with WHO and NACO Standards

Vinutha Gali, Thanka Johnson, Subhashini Paari, Dr. Afrin Fatima
article en

Abstract

Background: Blood transfusion is indispensable in trauma, surgery, cancer therapy, and anemia management. Because transfusion carries the risk of infection and immune reaction, blood banks must maintain strict quality control (QC). Objective: To evaluate the quality control performance of a tertiary care blood bank and determine its compliance with World Health Organization (WHO) and National AIDS Control Organization (NACO) standards. Methods: A one-year observational study was performed at the Blood Bank, Sree Balaji Medical College and Hospital. Data were collected from donor screening, component preparation, infectious-disease testing, storage, equipment monitoring, and transfusion-reaction surveillance. QC was assessed according to NACO (GSR 166-E, 11-03-2020) domains: infrastructure, donor screening, post-phlebotomy, test processing, bag quality, bag thawing, and discard. Results: During the three - month study period, 250 donors were screened, of whom 5 (2%) were deferred based on NACO donor selection criteria. A total of 245 blood units were collected and processed into blood components. One hundred quality control (QC) samples comprising packed red blood cells (PRBCs), random donor platelets (RDPs), and fresh frozen plasma (FFP) were evaluated. Serological screening revealed HBsAg positivity of 2.3%, HCV positivity of 0.7%, syphilis positivity of 0.3%, and no HIV-reactive donations. Among the QC samples, 98% of PRBCs, RDPs, and FFPs complied with WHO/NACO quality standards. Storage temperatures remained within recommended limits, all equipment passed scheduled calibration, and only mild transfusion reactions (2%) were observed. Conclusion: Comprehensive QC practices in this blood bank achieved 97.5 percent compliance with WHO/NACO requirements. Effective infrastructure, donor screening, and component monitoring ensure high product quality and safe transfusion outcomes.

Asia Pacific Journal of Health Management
Good health and well-being
Openalex Percentile: Top 8%
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon