Force-Sensor-Integrated Buckle for Wearable Robots

Wearable robots require compact sensing interfaces to monitor the forces transmitted through attachment straps. This study aims to combine strap fastening and force measurement in a lightweight buckle, enabling the magnitude and direction of strap loading to be monitored at the attachment interface. The proposed buckle incorporates two capacitive sensing cells and a flexure structure that converts applied loads into measurable capacitance changes. Their combined responses provide dual-axis force sensing within the buckle body. The complete device measures 64×45×10mm and weighs 34g, including its sensing and signal-processing electronics. Its force and angle ranges are 0–200N and ±8°, respectively. The average capacitance sensitivity was 1.33fF/N, and the force linearity error was 6.96% of full scale of output (FSO). Force root-mean-square error (RMSE) was 7.34% of FSO without initial preload and 1.21–1.76% of FSO with approximately 18N preload in the respective tests. The validation angle RMSE was 1.67% of FSO. Force hysteresis and repeatability were 8.88% and 0.51% of FSO, respectively. The force and angle FSO values were 200N and 16°. The estimated −3dB bandwidth was 2.7Hz. The proposed design provides a compact sensing interface for strap-based wearable robots.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-26
DOI
https://doi.org/10.3390/s26216772
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Force-Sensor-Integrated Buckle for Wearable Robots

Hyouk Ryeol Choi, Cheol Hoon Park, J. W. Hwang, Uikyum Kim et al.
Sensors
Sensor Technology and Measurement Systems
article

Force-Sensor-Integrated Buckle for Wearable Robots

Hyouk Ryeol Choi, Cheol Hoon Park, J. W. Hwang, Uikyum Kim, Heeyeon Jeong, Seong Jun Park, Seran Lee
article en

Abstract

Wearable robots require compact sensing interfaces to monitor the forces transmitted through attachment straps. This study aims to combine strap fastening and force measurement in a lightweight buckle, enabling the magnitude and direction of strap loading to be monitored at the attachment interface. The proposed buckle incorporates two capacitive sensing cells and a flexure structure that converts applied loads into measurable capacitance changes. Their combined responses provide dual-axis force sensing within the buckle body. The complete device measures 64×45×10mm and weighs 34g, including its sensing and signal-processing electronics. Its force and angle ranges are 0–200N and ±8°, respectively. The average capacitance sensitivity was 1.33fF/N, and the force linearity error was 6.96% of full scale of output (FSO). Force root-mean-square error (RMSE) was 7.34% of FSO without initial preload and 1.21–1.76% of FSO with approximately 18N preload in the respective tests. The validation angle RMSE was 1.67% of FSO. Force hysteresis and repeatability were 8.88% and 0.51% of FSO, respectively. The force and angle FSO values were 200N and 16°. The estimated −3dB bandwidth was 2.7Hz. The proposed design provides a compact sensing interface for strap-based wearable robots.

SensorsVol. 26(21)
Korea Institute of Machinery & Materials (KR), Sungkyunkwan University (KR)
Openalex Percentile: Top 12%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon