Machine learning for advancing gamma source localization in a human phantom using NaI (Tl) detector spectra in radiobioassay

This study introduces a machine learning (ML) based framework for the anatomical localization of gamma radiation sources in a human phantom (i.e., RMCII) using energy spectra from a NaI (Tl) scintillation detector, aiming to enhance internal dose assessment accuracy in radiobioassay. Spectra from Co-60, Cs-137, and Ba-133 placed in GI, lung, thyroid, and whole-body (WB) organs were recorded using a whole-body counter. After background subtraction and Min–Max normalization, ten statistical features (mean, skewness, kurtosis, entropy, interquartile range, etc.) have been extracted from each spectrum. A modular classification strategy trained four ML models (i.e., logistic regression (LR), decision tree (DT), support vector machine (SVM), multilayer perceptron (MLP)) for each isotope-detector configuration. LR achieved 100% localization accuracy when the detector was positioned in front of the GI organ with thyroid spectra excluded, while DT achieved up to 97.4% under the same conditions. However, performance dropped for Ba-133 due to spectral overlaps and attenuation, and for the WB detector position due to geometric symmetry. SVM and MLP performed poorly due to limited data and feature sensitivity. This modular, feature-based approach demonstrates the feasibility of ML for source localization in constrained radiobioassay settings, with LR and DT emerging as the most reliable classifiers, while highlighting challenges for low-energy isotopes and symmetric geometries that require future investigation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-10-28
DOI
https://doi.org/10.1038/s41598-026-78522-1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning for advancing gamma source localization in a human phantom using NaI (Tl) detector spectra in radiobioassay

Soroush Mohtashami, زهرا لشنی, Khalil Moshkbar-Bakhshayesh
Scientific Reports
Radiation Detection and Scintillator Technologies
article

Machine learning for advancing gamma source localization in a human phantom using NaI (Tl) detector spectra in radiobioassay

Soroush Mohtashami, زهرا لشنی, Khalil Moshkbar-Bakhshayesh
article en

Abstract

This study introduces a machine learning (ML) based framework for the anatomical localization of gamma radiation sources in a human phantom (i.e., RMCII) using energy spectra from a NaI (Tl) scintillation detector, aiming to enhance internal dose assessment accuracy in radiobioassay. Spectra from Co-60, Cs-137, and Ba-133 placed in GI, lung, thyroid, and whole-body (WB) organs were recorded using a whole-body counter. After background subtraction and Min–Max normalization, ten statistical features (mean, skewness, kurtosis, entropy, interquartile range, etc.) have been extracted from each spectrum. A modular classification strategy trained four ML models (i.e., logistic regression (LR), decision tree (DT), support vector machine (SVM), multilayer perceptron (MLP)) for each isotope-detector configuration. LR achieved 100% localization accuracy when the detector was positioned in front of the GI organ with thyroid spectra excluded, while DT achieved up to 97.4% under the same conditions. However, performance dropped for Ba-133 due to spectral overlaps and attenuation, and for the WB detector position due to geometric symmetry. SVM and MLP performed poorly due to limited data and feature sensitivity. This modular, feature-based approach demonstrates the feasibility of ML for source localization in constrained radiobioassay settings, with LR and DT emerging as the most reliable classifiers, while highlighting challenges for low-energy isotopes and symmetric geometries that require future investigation.

Scientific Reports
Sharif University of Technology (IR), Amirkabir University of Technology (IR), Islamic Azad University Central Tehran Branch (IR)
Good health and well-being
Openalex Percentile: Top 14%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon