Time-of-Day-Associated Variation in Serum CO2 Patient-Result Distribution and Its Impact on PBRTQC Performance

Background: Patient-based real-time quality control (PBRTQC) is now widely used in clinical labs, yet the impact of time-dependent variation on its performance remains understudied, particularly with regard to serum carbon dioxide (CO2). This study explores how time-of-day-associated variation in the serum CO2 patient-result distribution affects PBRTQC outcomes and clinical acidosis classification, and an optimization strategy is evaluated. Methods: We analyzed 168,957 serum CO2 results collected over one year (2025) using three biochemical analyzers. Moving average-based PBRTQC was compared between peak (10:00–13:00) and off-peak periods, using either conventional unified limits or time-stratified separate limits. Results: Serum CO2 patient-result distribution shifted significantly toward higher values during the peak period (23.6 vs. 23.0 mmol/L, p < 0.001). A unified control strategy led to a marked rise in false-positive rates (0.955% vs. 0.062%). In a simulated category-transition analysis, 92 of 1212 samples (7.59%) were reclassified, of which 88 were acidosis-to-normal shifts. The time-stratified model reduced peak false positives to 0.069% while maintaining efficient detection of error. Conclusions: Time-of-day-associated variation in the distribution of patients’ serum CO2 impairs PBRTQC specificity during peak hours. Time-stratified control limits reduce false-positive rates while maintaining error detection, offering a practical solution for reliable serum CO2 monitoring. These findings should be interpreted as descriptive, given the cross-sectional design and the potential influence of patient case mix.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-10-26
DOI
https://doi.org/10.3390/diagnostics16213504
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-of-Day-Associated Variation in Serum CO2 Patient-Result Distribution and Its Impact on PBRTQC Performance

Xuemei Wei, Jie Feng, Yanhong Gao, Ziqing Jiang et al.
Diagnostics
Clinical Laboratory Practices and Quality Control
article

Time-of-Day-Associated Variation in Serum CO2 Patient-Result Distribution and Its Impact on PBRTQC Performance

Xuemei Wei, Jie Feng, Yanhong Gao, Ziqing Jiang, Lei Lin
article en

Abstract

Background: Patient-based real-time quality control (PBRTQC) is now widely used in clinical labs, yet the impact of time-dependent variation on its performance remains understudied, particularly with regard to serum carbon dioxide (CO2). This study explores how time-of-day-associated variation in the serum CO2 patient-result distribution affects PBRTQC outcomes and clinical acidosis classification, and an optimization strategy is evaluated. Methods: We analyzed 168,957 serum CO2 results collected over one year (2025) using three biochemical analyzers. Moving average-based PBRTQC was compared between peak (10:00–13:00) and off-peak periods, using either conventional unified limits or time-stratified separate limits. Results: Serum CO2 patient-result distribution shifted significantly toward higher values during the peak period (23.6 vs. 23.0 mmol/L, p < 0.001). A unified control strategy led to a marked rise in false-positive rates (0.955% vs. 0.062%). In a simulated category-transition analysis, 92 of 1212 samples (7.59%) were reclassified, of which 88 were acidosis-to-normal shifts. The time-stratified model reduced peak false positives to 0.069% while maintaining efficient detection of error. Conclusions: Time-of-day-associated variation in the distribution of patients’ serum CO2 impairs PBRTQC specificity during peak hours. Time-stratified control limits reduce false-positive rates while maintaining error detection, offering a practical solution for reliable serum CO2 monitoring. These findings should be interpreted as descriptive, given the cross-sectional design and the potential influence of patient case mix.

DiagnosticsVol. 16(21)
Chinese PLA General Hospital (CN), First Affiliated Hospital of Chinese PLA General Hospital (CN)
Openalex Percentile: Top 12%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Time-of-Day-Associated Variation in Serum CO2 Patient-Result Distribution and Its Impact on PBRTQC Performance — Xuemei Wei, Jie Feng, et al. · Diagnostics (2026) | TGRS Research Map | TGRS