IMPROVING THERMAL COOLING SYSTEMS FOR ELECTRIC VEHICLE BATTERIES: A COMPARATIVE NUMERICAL STUDY AND META-ANALYSIS

The thermal management of the lithium-ion battery is one of the main factors which determine the safety, the fast-charging capability and the service life of the electric vehicles, and this is applied especially on the hot climates such as the Gulf region. In this paper, a reduced-order thermal network of a ten-cell 21700 module was developed, and it was used to compare six cooling strategies, namely the natural air, the forced air, the indirect liquid cold plate, the phase change material (PCM), the hybrid PCM-liquid and the single-phase immersion cooling, at the discharge rates of 1C, 2C and 3C and at the ambient temperatures of 25 C and 40 C. In addition, a random-effects meta-analysis of eight published comparisons was conducted. The results showed that, at 3C and 25 C, the peak core temperature was reduced from 58.27 C under the natural air to 34.02 C under the immersion cooling and to 34.45 C under the hybrid PCM-liquid system.

Authors

Institutions

Publication Details

Journal
International Journal of Advanced Research
Published
2026-10-27
DOI
https://doi.org/10.21474/ijar01/24382
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMPROVING THERMAL COOLING SYSTEMS FOR ELECTRIC VEHICLE BATTERIES: A COMPARATIVE NUMERICAL STUDY AND META-ANALYSIS

Idrees M. A. Alkandari
6 links
International Journal of Advanced Research
Advanced Battery Technologies Research
article

IMPROVING THERMAL COOLING SYSTEMS FOR ELECTRIC VEHICLE BATTERIES: A COMPARATIVE NUMERICAL STUDY AND META-ANALYSIS

Idrees M. A. Alkandari
article en

Abstract

The thermal management of the lithium-ion battery is one of the main factors which determine the safety, the fast-charging capability and the service life of the electric vehicles, and this is applied especially on the hot climates such as the Gulf region. In this paper, a reduced-order thermal network of a ten-cell 21700 module was developed, and it was used to compare six cooling strategies, namely the natural air, the forced air, the indirect liquid cold plate, the phase change material (PCM), the hybrid PCM-liquid and the single-phase immersion cooling, at the discharge rates of 1C, 2C and 3C and at the ambient temperatures of 25 C and 40 C. In addition, a random-effects meta-analysis of eight published comparisons was conducted. The results showed that, at 3C and 25 C, the peak core temperature was reduced from 58.27 C under the natural air to 34.02 C under the immersion cooling and to 34.45 C under the hybrid PCM-liquid system.

International Journal of Advanced ResearchVol. 14(10)
Public Authority for Applied Education and Training (KW), Al-Sabah Hospital (KW)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Openalex Percentile: Top 23%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
IMPROVING THERMAL COOLING SYSTEMS FOR ELECTRIC VEHICLE BATTERIES: A COMPARATIVE NUMERICAL STUDY AND META-ANALYSIS — Idrees M. A. Alkandari · International Journal of Advanced Research (2026) | TGRS Research Map | TGRS