Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily Activities

Musculoskeletal (MSK) modelling enables non-invasive estimation of internal body loads, which could inform the design of novel orthopedic implants and guide personalized treatment strategies. Extensive validation is a pre-requisite for the translation of MSK-modelling frameworks into clinical applications. This study validates predicted knee loads and local kinematics across multiple activities of daily living (ADLs) using motion-capture data from 184 activity cycles collected in six subjects performing five ADLs from the CAMS-Knee datasets. Personalized models incorporated subject-specific anthropometric, radiographic, and implantation data, along with a 6-DOF elastic-foundation contact model between implant components and a surgically balanced ligament model derived from cadaveric testing. Across activities, predicted knee contact force magnitudes showed good agreement with instrumented implant measurements (RMSE 0.46 BW; R 2 = 0.81). The highest accuracy was found during level walking, whereas stair descent exhibited the largest discrepancies. Predicted implant kinematics showed qualitatively similar trends to fluoroscopic measurements across all ADLs, although with varying levels of accuracy across different degrees of freedom. EMG comparisons revealed broadly consistent activation timing between model predictions and experimental data, although gastrocnemius activation was poorly estimated during stair descent and downhill walking. By validating MSK model predictions across the complete range of activities available in the CAMS-Knee datasets, this study extends validation beyond previously analysed gait or bending tasks and reveals activity-specific discrepancies that reflect current limitations in modelling assumptions and would remain undetected in single-activity analyses. These findings provide a robust basis for future refinement of MSK models and support their development toward clinically meaningful applications.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-10-27
DOI
https://doi.org/10.64898/2026.10.24.761008
Primary Topic
Knee injuries and reconstruction techniques
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily Activities

Pascal Schütz, William R. Taylor, Philipp Damm, Sara C. Sarabadani Tafreshi et al.
2 links
bioRxiv (Cold Spring Harbor Laboratory)
Knee injuries and reconstruction techniques
preprint

Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily Activities

Pascal Schütz, William R. Taylor, Philipp Damm, Sara C. Sarabadani Tafreshi, Morten Enemark Lund, Enrico De Pieri, Jörn Seebeck, Marc Bandi, Sabrina Hoermann
preprint en

Abstract

Musculoskeletal (MSK) modelling enables non-invasive estimation of internal body loads, which could inform the design of novel orthopedic implants and guide personalized treatment strategies. Extensive validation is a pre-requisite for the translation of MSK-modelling frameworks into clinical applications. This study validates predicted knee loads and local kinematics across multiple activities of daily living (ADLs) using motion-capture data from 184 activity cycles collected in six subjects performing five ADLs from the CAMS-Knee datasets. Personalized models incorporated subject-specific anthropometric, radiographic, and implantation data, along with a 6-DOF elastic-foundation contact model between implant components and a surgically balanced ligament model derived from cadaveric testing. Across activities, predicted knee contact force magnitudes showed good agreement with instrumented implant measurements (RMSE 0.46 BW; R 2 = 0.81). The highest accuracy was found during level walking, whereas stair descent exhibited the largest discrepancies. Predicted implant kinematics showed qualitatively similar trends to fluoroscopic measurements across all ADLs, although with varying levels of accuracy across different degrees of freedom. EMG comparisons revealed broadly consistent activation timing between model predictions and experimental data, although gastrocnemius activation was poorly estimated during stair descent and downhill walking. By validating MSK model predictions across the complete range of activities available in the CAMS-Knee datasets, this study extends validation beyond previously analysed gait or bending tasks and reveals activity-specific discrepancies that reflect current limitations in modelling assumptions and would remain undetected in single-activity analyses. These findings provide a robust basis for future refinement of MSK models and support their development toward clinically meaningful applications.

bioRxiv (Cold Spring Harbor Laboratory)
ETH Zurich (CH), Zimmer Biomet (Germany) (DE), AnyBody Technology (Denmark) (DK), Schulthess-Klinik (CH), Zimmer Biomet (United States) (US), Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE), Institute for Biomechanics (CH), Charité - Universitätsmedizin Berlin (DE), Zimmer Biomet (Switzerland) (CH), Delft University of Technology (NL)
Innosuisse - Schweizerische Agentur für Innovationsförderung
Good health and well-being
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.