Biomechanical evaluation of rescue configurations following posterior implant loss in all-on-4 rehabilitation under different occlusal loads: a finite element analysis

This study aimed to evaluate stress distribution and prosthetic displacement associated with different implant configurations used as biomechanical rescue strategies following posterior implant loss in All-on-4 rehabilitation under functional and parafunctional occlusal loads. Three-dimensional finite element models were developed using computed tomography data of an edentulous maxilla to simulate three rehabilitation scenarios following posterior implant loss in a maxillary All-on-4 case. Model 1 (M1) restored the original All-on-4 configuration using a new tilted posterior implant. Model 2 (M2) combined three conventional implants with a subperiosteal implant featuring two abutment exits, while Model 3 (M3) simulated replacement of the lost implant with a zygomatic implant. All models incorporated screw-retained full-arch polymethyl methacrylate prostheses supported by titanium frameworks. Functional unilateral loading scenarios included: Load 1, a 450 N vertical posterior load distributed over the first premolar, second premolar, and first molar; Load 2, a 93 N oblique canine-guided load applied at 45° from the palatal-to-buccal direction; and Load 3, a 200 N oblique group-function load applied at 30° to the premolar and molar buccal cusps. Parafunctional loading scenarios included: Load 4, a 1000 N vertical posterior load; Load 5, a 250 N oblique canine-guided load; and Load 6, a 500 N oblique group-function load applied to the same contact points. The highest cortical bone stress was observed in M1 under Load 4 (95.944 MPa), whereas the highest implant-body stress was recorded at the posterior abutment exit of M2 under Load 6 (630.449 MPa). The highest framework stress was observed in M1 under Load 4 (448.413 MPa), whereas the greatest prosthetic displacement occurred in M1 under Load 6 (0.442 mm). The lowest framework stress and prosthetic displacement were recorded in M2 under Load 1 (58.971 MPa; 0.050 mm, respectively). The subperiosteal rescue configuration generally showed lower bone and framework stresses and prosthetic displacement, although high implant-body stress was observed under parafunctional loading. The conventional All-on-4 rescue configuration showed greater mechanical demand within the superstructure. The zygomatic rescue configuration exhibited intermediate performance. Parafunctional loading and group-function loading generated less favorable biomechanical responses than functional loading and canine-guided loading. Posterior implant loss in All-on-4 rehabilitation presents a clinical challenge, particularly in patients with parafunctional habits. This study evaluates the biomechanical performance of subperiosteal and zygomatic rescue configurations following posterior implant loss in All-on-4 rehabilitation under different occlusal loading conditions. The findings may provide preliminary biomechanical information to support treatment planning in patients with elevated occlusal risk.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-10-27
DOI
https://doi.org/10.1186/s12903-026-10301-w
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of rescue configurations following posterior implant loss in all-on-4 rehabilitation under different occlusal loads: a finite element analysis

Berkman ALBAYRAK, İzim Türker Kader, Gulsum Sayin Ozel, Simge Dagistan et al.
4 links
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Biomechanical evaluation of rescue configurations following posterior implant loss in all-on-4 rehabilitation under different occlusal loads: a finite element analysis

Berkman ALBAYRAK, İzim Türker Kader, Gulsum Sayin Ozel, Simge Dagistan, Serra Oğuz Ahmet
article en

Abstract

This study aimed to evaluate stress distribution and prosthetic displacement associated with different implant configurations used as biomechanical rescue strategies following posterior implant loss in All-on-4 rehabilitation under functional and parafunctional occlusal loads. Three-dimensional finite element models were developed using computed tomography data of an edentulous maxilla to simulate three rehabilitation scenarios following posterior implant loss in a maxillary All-on-4 case. Model 1 (M1) restored the original All-on-4 configuration using a new tilted posterior implant. Model 2 (M2) combined three conventional implants with a subperiosteal implant featuring two abutment exits, while Model 3 (M3) simulated replacement of the lost implant with a zygomatic implant. All models incorporated screw-retained full-arch polymethyl methacrylate prostheses supported by titanium frameworks. Functional unilateral loading scenarios included: Load 1, a 450 N vertical posterior load distributed over the first premolar, second premolar, and first molar; Load 2, a 93 N oblique canine-guided load applied at 45° from the palatal-to-buccal direction; and Load 3, a 200 N oblique group-function load applied at 30° to the premolar and molar buccal cusps. Parafunctional loading scenarios included: Load 4, a 1000 N vertical posterior load; Load 5, a 250 N oblique canine-guided load; and Load 6, a 500 N oblique group-function load applied to the same contact points. The highest cortical bone stress was observed in M1 under Load 4 (95.944 MPa), whereas the highest implant-body stress was recorded at the posterior abutment exit of M2 under Load 6 (630.449 MPa). The highest framework stress was observed in M1 under Load 4 (448.413 MPa), whereas the greatest prosthetic displacement occurred in M1 under Load 6 (0.442 mm). The lowest framework stress and prosthetic displacement were recorded in M2 under Load 1 (58.971 MPa; 0.050 mm, respectively). The subperiosteal rescue configuration generally showed lower bone and framework stresses and prosthetic displacement, although high implant-body stress was observed under parafunctional loading. The conventional All-on-4 rescue configuration showed greater mechanical demand within the superstructure. The zygomatic rescue configuration exhibited intermediate performance. Parafunctional loading and group-function loading generated less favorable biomechanical responses than functional loading and canine-guided loading. Posterior implant loss in All-on-4 rehabilitation presents a clinical challenge, particularly in patients with parafunctional habits. This study evaluates the biomechanical performance of subperiosteal and zygomatic rescue configurations following posterior implant loss in All-on-4 rehabilitation under different occlusal loading conditions. The findings may provide preliminary biomechanical information to support treatment planning in patients with elevated occlusal risk.

BMC Oral Health
Bahçeşehir University (TR), Istanbul Medipol University (TR)
Good health and well-being
Openalex Percentile: Top 10%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon