EVALUATION OF SOME MECHANICAL PROPERTIES OF POLY ETHER-ETHER-KETONE AS ALTERNATIVE TO POLYMETHYL-METH-ACRYLATE DENTURE BASE MATERIAL (AN IN VITRO STUDY)

Objectives: This in-vitro study was conducted to evaluate and compare the flexural strength and water sorption of a high-performance thermoplastic polymer, Polyetheretherketone (PEEK), against conventional heat-cured polymethylmethacrylate (PMMA) denture base material. Methods: Forty specimens were divided into PEEK (Group K, n=20) and PMMA (Group C, n=20) groups, then subdivided (n=10) for testing. For the flexural strength test, rectangular specimens (65×10×2.5 mm) were evaluated via a three-point bending test on an Instron 3345 machine in accordance with ISO 20795-1 at a crosshead speed of 5 mm/min. For the water sorption test, disc specimens (10 mm diameter × 2 mm thickness) were desiccator-dried to a constant weight, then immersed in distilled water at 37°C for one week. Weight changes were recorded using a highly precise four-digit analytical balance in accordance with ISO 20795-1 specifications. Statistical analysis was performed using Student’s t-test with the significance level set at (p < 0.05). Results: Statistical analysis revealed that the PEEK group recorded a significantly higher mean flexural strength (196.1 ± 7.6 MPa) compared to the PMMA group (125.6 ± 6.4 MPa) (p < 0.0001). Conversely, the PMMA group demonstrated a significantly higher mean water sorption percentage (0.65 ± 0.24%) than the PEEK group (0.30 ± 0.11%) (p < 0.0001). Conclusions: CAD/CAM-milled PEEK demonstrated superior flexural strength and significantly lower water sorption compared to PMMA. Consequently, it offers a highly durable, dimensionally stable alternative to overcome conventional acrylic resin limitations. Clinical relevance: Using CAD/CAM PEEK denture bases directly minimizes common clinical failures, such as midline fractures and partial denture clasp breakage. Furthermore, its minimal fluid absorption ensures long-term dimensional stability, color preservation, and excellent fit inside the oral cavity. Additionally, its biocompatible, monomer-free nature completely eliminates the risk of patient allergic reactions and mucosal irritation.

Authors

Institutions

Publication Details

Journal
Acta Innovations
Published
2026-10-26
DOI
https://doi.org/10.62441/actainnovations.vi.2456
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF SOME MECHANICAL PROPERTIES OF POLY ETHER-ETHER-KETONE AS ALTERNATIVE TO POLYMETHYL-METH-ACRYLATE DENTURE BASE MATERIAL (AN IN VITRO STUDY)

Ahmed Ali Ezzeldine, Sara Zaky, Mohammed Hassan, Ahmed Mohamed Abu Siyam et al.
Acta Innovations
Dental materials and restorations
article

EVALUATION OF SOME MECHANICAL PROPERTIES OF POLY ETHER-ETHER-KETONE AS ALTERNATIVE TO POLYMETHYL-METH-ACRYLATE DENTURE BASE MATERIAL (AN IN VITRO STUDY)

Ahmed Ali Ezzeldine, Sara Zaky, Mohammed Hassan, Ahmed Mohamed Abu Siyam, Mohammed Osman, Ahmed Ezzat Ahmed Al-Gazzar, Osama Abedlhamid Saad Helaly, Ahmad Mohamaed Mahmoud Hassan Shoeib, Mamdouh Mohamed Abdelhady Mansour
article en

Abstract

Objectives: This in-vitro study was conducted to evaluate and compare the flexural strength and water sorption of a high-performance thermoplastic polymer, Polyetheretherketone (PEEK), against conventional heat-cured polymethylmethacrylate (PMMA) denture base material. Methods: Forty specimens were divided into PEEK (Group K, n=20) and PMMA (Group C, n=20) groups, then subdivided (n=10) for testing. For the flexural strength test, rectangular specimens (65×10×2.5 mm) were evaluated via a three-point bending test on an Instron 3345 machine in accordance with ISO 20795-1 at a crosshead speed of 5 mm/min. For the water sorption test, disc specimens (10 mm diameter × 2 mm thickness) were desiccator-dried to a constant weight, then immersed in distilled water at 37°C for one week. Weight changes were recorded using a highly precise four-digit analytical balance in accordance with ISO 20795-1 specifications. Statistical analysis was performed using Student’s t-test with the significance level set at (p < 0.05). Results: Statistical analysis revealed that the PEEK group recorded a significantly higher mean flexural strength (196.1 ± 7.6 MPa) compared to the PMMA group (125.6 ± 6.4 MPa) (p < 0.0001). Conversely, the PMMA group demonstrated a significantly higher mean water sorption percentage (0.65 ± 0.24%) than the PEEK group (0.30 ± 0.11%) (p < 0.0001). Conclusions: CAD/CAM-milled PEEK demonstrated superior flexural strength and significantly lower water sorption compared to PMMA. Consequently, it offers a highly durable, dimensionally stable alternative to overcome conventional acrylic resin limitations. Clinical relevance: Using CAD/CAM PEEK denture bases directly minimizes common clinical failures, such as midline fractures and partial denture clasp breakage. Furthermore, its minimal fluid absorption ensures long-term dimensional stability, color preservation, and excellent fit inside the oral cavity. Additionally, its biocompatible, monomer-free nature completely eliminates the risk of patient allergic reactions and mucosal irritation.

Acta InnovationsVol. 63(3s)
Suez Canal University (EG), Al-Azhar University (EG), Al-Azhar University (ID), Assiut University (EG)
Openalex Percentile: Top 9%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon