Functional Prosthetic Valve Dysfunction: An Underrecognized Cause of Elevated Transprosthetic Gradients

Background: Elevated transprosthetic gradients are commonly considered a sign of prosthetic valve obstruction. However, certain haemodynamic or physiological conditions may result in increased gradients despite a structurally normal prosthesis. Recognizing these functional abnormalities is essential to avoid misdiagnosis of prosthetic obstruction and inappropriate management. Aims: To assess the frequency and principal clinical, echocardiographic and aetiological characteristics of functional prosthetic valve dysfunction associated with elevated transprosthetic gradients in a single-centre cohort. Methodology: We conducted a retrospective single-centre study at the Department of Cardiology, Mohammed VI University Hospital, Marrakech, including 77 patients with prosthetic valve dysfunction. Clinical, transthoracic and transoesophageal echocardiographic data, together with laboratory data, were analysed. Functional prosthetic valve dysfunction was defined as elevated transprosthetic gradients in the absence of morphological evidence of prosthetic obstruction, with an identified haemodynamic or physiological condition explaining the increased gradients. Results: Functional prosthetic valve dysfunction was identified in 9 of 77 patients (11.7%). The mean age was 55.9 ± 14.3 years, with a female predominance (66.7%). The main underlying conditions were severe anaemia in 4 patients (44.4%), hyperthyroidism in 2 patients (22.2%), patient–prosthesis mismatch in 2 patients (22.2%), and pregnancy in 1 patient (11.1%). All patients were symptomatic, with NYHA functional class II in 3 patients and class III in 6 patients. The mean transprosthetic gradient was 10.3 ± 1.6 mmHg across mitral prostheses and 30.3 ± 7.0 mmHg across aortic prostheses. No definitive morphological evidence of thrombus or pannus was identified in this subgroup. Conclusion: Functional prosthetic valve dysfunction accounted for 11.7% of prosthetic valve dysfunctions in our series. Severe anaemia, hyperthyroidism, patient–prosthesis mismatch, and pregnancy were the main associated conditions. An elevated transprosthetic gradient should therefore not be interpreted in isolation as evidence of prosthetic obstruction. Its assessment should integrate transvalvular flow, Doppler parameters, the clinical context, and prosthetic valve morphology.

Authors

Institutions

Publication Details

Journal
Cardiology and Angiology An International Journal
Published
2026-10-27
DOI
https://doi.org/10.9734/ca/2026/v15i4571
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional Prosthetic Valve Dysfunction: An Underrecognized Cause of Elevated Transprosthetic Gradients

El Hattaoui Mustapha, Fadwa Haffane, Elmassraoui Joumana, El Karimi Saloua et al.
Cardiology and Angiology An International Journal
Cardiac Valve Diseases and Treatments
article

Functional Prosthetic Valve Dysfunction: An Underrecognized Cause of Elevated Transprosthetic Gradients

El Hattaoui Mustapha, Fadwa Haffane, Elmassraoui Joumana, El Karimi Saloua, Elaakib Khaoula, Oudadda Soumaya
article en

Abstract

Background: Elevated transprosthetic gradients are commonly considered a sign of prosthetic valve obstruction. However, certain haemodynamic or physiological conditions may result in increased gradients despite a structurally normal prosthesis. Recognizing these functional abnormalities is essential to avoid misdiagnosis of prosthetic obstruction and inappropriate management. Aims: To assess the frequency and principal clinical, echocardiographic and aetiological characteristics of functional prosthetic valve dysfunction associated with elevated transprosthetic gradients in a single-centre cohort. Methodology: We conducted a retrospective single-centre study at the Department of Cardiology, Mohammed VI University Hospital, Marrakech, including 77 patients with prosthetic valve dysfunction. Clinical, transthoracic and transoesophageal echocardiographic data, together with laboratory data, were analysed. Functional prosthetic valve dysfunction was defined as elevated transprosthetic gradients in the absence of morphological evidence of prosthetic obstruction, with an identified haemodynamic or physiological condition explaining the increased gradients. Results: Functional prosthetic valve dysfunction was identified in 9 of 77 patients (11.7%). The mean age was 55.9 ± 14.3 years, with a female predominance (66.7%). The main underlying conditions were severe anaemia in 4 patients (44.4%), hyperthyroidism in 2 patients (22.2%), patient–prosthesis mismatch in 2 patients (22.2%), and pregnancy in 1 patient (11.1%). All patients were symptomatic, with NYHA functional class II in 3 patients and class III in 6 patients. The mean transprosthetic gradient was 10.3 ± 1.6 mmHg across mitral prostheses and 30.3 ± 7.0 mmHg across aortic prostheses. No definitive morphological evidence of thrombus or pannus was identified in this subgroup. Conclusion: Functional prosthetic valve dysfunction accounted for 11.7% of prosthetic valve dysfunctions in our series. Severe anaemia, hyperthyroidism, patient–prosthesis mismatch, and pregnancy were the main associated conditions. An elevated transprosthetic gradient should therefore not be interpreted in isolation as evidence of prosthetic obstruction. Its assessment should integrate transvalvular flow, Doppler parameters, the clinical context, and prosthetic valve morphology.

Cardiology and Angiology An International JournalVol. 15(4)
Centre Hospitalier Universitaire Mohammed VI (MA)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon