ClinLab-RAG: A Multimodal RAG System for the Early Verification of Risks in Medical Equipment Supply Chains

Checking manually whether a reagent works on a given analyser takes a median of 12.3 min at the distributor we studied. We developed ClinLab-RAG, a retrieval-augmented generation architecture with hybrid search, a product compatibility graph and five LangGraph agents, and evaluated it through Design Science Research on 394 technical and ERP fragments and 175 queries. In the automated evaluation, the submitted architecture raised answer relevancy from 0.416 (keyword retrieval) to 0.522 while faithfulness fell from 0.945 to 0.724; component analyses attribute the gain to the specialised prompt and show that the graph raised context recall at the cost of faithfulness. A revised architecture checks compatibility against the manufacturer’s matrix and hazard classifications against the source safety data sheet deterministically. It raised context recall from 0.416 to 0.460, gave correct verdicts for every recognised equipment–reagent pair and included the complete GHS classification in 14 of 17 safety answers, against 1 of 17 before. Three blinded domain experts rated v2 and the strongest baseline near the ceiling (exactness 1.95 vs. 1.89 of 2; p = 0.180). The system supports verification before dispatch; its effect on procurement errors remains to be measured.

Authors

Institutions

Publication Details

Journal
Mathematical and Computational Applications
Published
2026-10-26
DOI
https://doi.org/10.3390/mca31060235
Primary Topic
Topic Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ClinLab-RAG: A Multimodal RAG System for the Early Verification of Risks in Medical Equipment Supply Chains

Pablo Marcel Recalde Varela, Paúl Francisco Baldeón Egas, Diego Gonzalo Pozo Salas
Mathematical and Computational Applications
Topic Modeling
article

ClinLab-RAG: A Multimodal RAG System for the Early Verification of Risks in Medical Equipment Supply Chains

Pablo Marcel Recalde Varela, Paúl Francisco Baldeón Egas, Diego Gonzalo Pozo Salas
article en

Abstract

Checking manually whether a reagent works on a given analyser takes a median of 12.3 min at the distributor we studied. We developed ClinLab-RAG, a retrieval-augmented generation architecture with hybrid search, a product compatibility graph and five LangGraph agents, and evaluated it through Design Science Research on 394 technical and ERP fragments and 175 queries. In the automated evaluation, the submitted architecture raised answer relevancy from 0.416 (keyword retrieval) to 0.522 while faithfulness fell from 0.945 to 0.724; component analyses attribute the gain to the specialised prompt and show that the graph raised context recall at the cost of faithfulness. A revised architecture checks compatibility against the manufacturer’s matrix and hazard classifications against the source safety data sheet deterministically. It raised context recall from 0.416 to 0.460, gave correct verdicts for every recognised equipment–reagent pair and included the complete GHS classification in 14 of 17 safety answers, against 1 of 17 before. Three blinded domain experts rated v2 and the strongest baseline near the ceiling (exactness 1.95 vs. 1.89 of 2; p = 0.180). The system supports verification before dispatch; its effect on procurement errors remains to be measured.

Mathematical and Computational ApplicationsVol. 31(6)
Universidad Israel (EC)
Openalex Percentile: Top 13%
Topic Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon