Joint Geometry Controls Preferential Flow and Contaminant Transport in HDPE Geomembrane Composite Cutoff Walls

High-density polyethylene (HDPE) geomembrane composite cutoff walls are used to limit groundwater flow and contaminant migration, but panel joints can form localized transport pathways. The unresolved question is how predefined interlocking configurations differ in joint-controlled flow and transport. This component-scale study combined individual 20 g geotechnical centrifuge tests with local-scale, engineering-width, and three-dimensional centrifuge-apparatus numerical models to compare crescent-shaped, square, and triangular joint configurations. Two-dimensional local-scale models provided configuration-specific equivalent hydraulic conductivity and diffusion coefficients, which were transferred without calibration to a three-dimensional half-domain model of the centrifuge apparatus. Separate 6.0 m-wide two-dimensional calculations quantified the contribution of the joints and prescribed cracks to overall equivalent hydraulic conductivity. The crescent-shaped joint showed the smallest measured hydraulic-head reduction and the lowest local-scale equivalent hydraulic conductivity, whereas the triangular joint showed the largest values. The centrifuge Na+ changes were within the stated instrumental error and were retained only as descriptive records. Extended 10 d constant-head analyses using the 0.40 m three-dimensional half-domain indicated that the maximum external-domain Na+ concentration increased with hydraulic-head difference and that prescribed cracks accelerated the concentration response; differences among the 0.5–1.5 mm crack cases were small and non-monotonic at 10 d. The simulated concentration fields illustrate joint-controlled contaminant transfer into a common receiving-fluid domain at the component scale. The comparison provides a practical basis for joint detailing, defect control, and construction quality assurance in composite cutoff walls.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-10-26
DOI
https://doi.org/10.3390/buildings16214275
Primary Topic
Landfill Environmental Impact Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Joint Geometry Controls Preferential Flow and Contaminant Transport in HDPE Geomembrane Composite Cutoff Walls

Yu Diao, Chenlei Jiao, Zhenghao Qiao, Yiming Du et al.
Buildings
Landfill Environmental Impact Studies
article

Joint Geometry Controls Preferential Flow and Contaminant Transport in HDPE Geomembrane Composite Cutoff Walls

Yu Diao, Chenlei Jiao, Zhenghao Qiao, Yiming Du, Zhian Jiang, Maoxiang Guan, Baozeng Zhang, Baozhu Liu, Liang Shao, Zongling Wang, Rui Wang
article en

Abstract

High-density polyethylene (HDPE) geomembrane composite cutoff walls are used to limit groundwater flow and contaminant migration, but panel joints can form localized transport pathways. The unresolved question is how predefined interlocking configurations differ in joint-controlled flow and transport. This component-scale study combined individual 20 g geotechnical centrifuge tests with local-scale, engineering-width, and three-dimensional centrifuge-apparatus numerical models to compare crescent-shaped, square, and triangular joint configurations. Two-dimensional local-scale models provided configuration-specific equivalent hydraulic conductivity and diffusion coefficients, which were transferred without calibration to a three-dimensional half-domain model of the centrifuge apparatus. Separate 6.0 m-wide two-dimensional calculations quantified the contribution of the joints and prescribed cracks to overall equivalent hydraulic conductivity. The crescent-shaped joint showed the smallest measured hydraulic-head reduction and the lowest local-scale equivalent hydraulic conductivity, whereas the triangular joint showed the largest values. The centrifuge Na+ changes were within the stated instrumental error and were retained only as descriptive records. Extended 10 d constant-head analyses using the 0.40 m three-dimensional half-domain indicated that the maximum external-domain Na+ concentration increased with hydraulic-head difference and that prescribed cracks accelerated the concentration response; differences among the 0.5–1.5 mm crack cases were small and non-monotonic at 10 d. The simulated concentration fields illustrate joint-controlled contaminant transfer into a common receiving-fluid domain at the component scale. The comparison provides a practical basis for joint detailing, defect control, and construction quality assurance in composite cutoff walls.

BuildingsVol. 16(21)
Tianjin University (CN)
Openalex Percentile: Top 10%
Landfill Environmental Impact Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon