Relationship Between Pulse Oximetry and Arterial Oxygen Saturation During Rest and Exercise at Extreme Altitude

Manferdelli, Giorgio, Denis J. Wakeham, Keval D. Patel, Eric T. Hedge, Michael G. Leahy, Abel Thomas, James Berry, Tony G. Babb, Peter Hackett, Renie Guilliod, Benjamin D. Levine, Christopher M. Hearon, Jr., and Andrew R. Tomlinson. Relationship between pulse oximetry and arterial oxygen saturation during rest and exercise at extreme altitude. High Alt Med Biol. 00:00–00, 2026. Introduction: Pulse oximetry (SpO 2 ) is commonly used to guide oxygen use, including at high altitude, but its accuracy during severe hypoxemia remains uncertain. This study aimed to compare arterial oxygen saturation (SaO 2 ) and SpO 2 while using graded levels of supplemental oxygen at simulated extreme altitude in a hypobaric chamber. Methods: Four healthy, unacclimatized adults completed rest and 60 Watts of exercise at different flow rates of supplemental oxygen (6, 4, 2, 1, and 0 l/min nominal flow) at 282 mmHg barometric pressure (Pb; equivalent to 8,100 m) and 253 mmHg Pb (equivalent to 8,848 m) with simultaneous measurement of arterial blood gases (radial artery catheter) and SpO 2 (forehead pulse oximetry). Exercise was only performed at 282 mmHg. Results: Across all altitudes and conditions, SaO 2 and SpO 2 demonstrated a very strong correlation (all r 2 ≥ 0.95, p < 0.001), with SpO 2 showing a consistent positive bias (pooled: 1.7% [−4.4% to 7.7%]; 282 mmHg rest: 0.4% [−4.5% to 5.3%]; 282 mmHg exercise: 3.1% [−2.2% to 8.5%]; 253 mmHg rest: 2.9% [4.9% to 10.6%]). The magnitude of the SpO 2 bias was higher when only SaO 2 <70% was considered (pooled: 5.2%). The root mean square error was 2.6 for SaO 2 ≥70% and increased to 6.2 when SaO 2 was <70%. Conclusions: Although SpO 2 represents a precise noninvasive measure for SaO 2 across a wide range of oxygen saturations (70%–100%), SpO 2 has lower precision and accuracy during severe hypoxemia (<70% SaO 2 ).

Authors

Institutions

Publication Details

Journal
High Altitude Medicine & Biology
Published
2026-10-27
DOI
https://doi.org/10.1177/15578682261502207
Primary Topic
High Altitude and Hypoxia
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relationship Between Pulse Oximetry and Arterial Oxygen Saturation During Rest and Exercise at Extreme Altitude

Peter H. Hackett, Christopher M. Hearon, Denis J. Wakeham, Renie Guilliod et al.
1 links
High Altitude Medicine & Biology
High Altitude and Hypoxia
article

Relationship Between Pulse Oximetry and Arterial Oxygen Saturation During Rest and Exercise at Extreme Altitude

Peter H. Hackett, Christopher M. Hearon, Denis J. Wakeham, Renie Guilliod, Giorgio Manferdelli, Keval D. Patel, Tony G. Babb, Michael G. Leahy, Eric T. Hedge, Andrew R. Tomlinson, Benjamin D. Levine, James Berry, Abel Thomas
article en

Abstract

Manferdelli, Giorgio, Denis J. Wakeham, Keval D. Patel, Eric T. Hedge, Michael G. Leahy, Abel Thomas, James Berry, Tony G. Babb, Peter Hackett, Renie Guilliod, Benjamin D. Levine, Christopher M. Hearon, Jr., and Andrew R. Tomlinson. Relationship between pulse oximetry and arterial oxygen saturation during rest and exercise at extreme altitude. High Alt Med Biol. 00:00–00, 2026. Introduction: Pulse oximetry (SpO 2 ) is commonly used to guide oxygen use, including at high altitude, but its accuracy during severe hypoxemia remains uncertain. This study aimed to compare arterial oxygen saturation (SaO 2 ) and SpO 2 while using graded levels of supplemental oxygen at simulated extreme altitude in a hypobaric chamber. Methods: Four healthy, unacclimatized adults completed rest and 60 Watts of exercise at different flow rates of supplemental oxygen (6, 4, 2, 1, and 0 l/min nominal flow) at 282 mmHg barometric pressure (Pb; equivalent to 8,100 m) and 253 mmHg Pb (equivalent to 8,848 m) with simultaneous measurement of arterial blood gases (radial artery catheter) and SpO 2 (forehead pulse oximetry). Exercise was only performed at 282 mmHg. Results: Across all altitudes and conditions, SaO 2 and SpO 2 demonstrated a very strong correlation (all r 2 ≥ 0.95, p < 0.001), with SpO 2 showing a consistent positive bias (pooled: 1.7% [−4.4% to 7.7%]; 282 mmHg rest: 0.4% [−4.5% to 5.3%]; 282 mmHg exercise: 3.1% [−2.2% to 8.5%]; 253 mmHg rest: 2.9% [4.9% to 10.6%]). The magnitude of the SpO 2 bias was higher when only SaO 2 <70% was considered (pooled: 5.2%). The root mean square error was 2.6 for SaO 2 ≥70% and increased to 6.2 when SaO 2 was <70%. Conclusions: Although SpO 2 represents a precise noninvasive measure for SaO 2 across a wide range of oxygen saturations (70%–100%), SpO 2 has lower precision and accuracy during severe hypoxemia (<70% SaO 2 ).

High Altitude Medicine & Biology
Texas Health Dallas (US), Institute for Exercise and Environmental Medicine (US), University of Colorado Anschutz Medical Campus (US), The University of Texas Southwestern Medical Center (US)
Wilderness Medical Society
Good health and well-being
Openalex Percentile: Top 15%
High Altitude and Hypoxia
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon