Sensitive Level of Detection of Heavy Metals by Using PDA Detector in API and Formulation of Simvastatin
A simple, rapid and sensitive ultra-fast liquid chromatographic technique was developed for the determination of heavy metals in pharmaceutical dosage form. Lead and copper were detected and quantified at µg level in simvastatin, a pharmaceutical product used in the treatment of lowering cholesterol level in body. Calcium disodium edetate was used as the chelating agent.
Authors
- S. Shimna
- K. Hifathulla
- R. K. Sangeetha
- A. Rohith Kannan
Institutions
- Sri Ramakrishna Institute of Paramedical Sciences (IN)
Publication Details
- Journal
- International Journal of Innovative Science and Research Technology (IJISRT)
- Published
- 2026-10-27
- DOI
- https://doi.org/10.38124/ijisrt/26oct1016
- Primary Topic
- Analytical Methods in Pharmaceuticals
- Type
- article
- Field-Weighted Citation Impact
- 0.00