LFP/Graphite 18650 Cells Designed to Operate from 20 to 100oC for Studies of Degradation Mechanisms: Part 2 – Arrhenius Parameter Extraction and Lifetime Modelling

Abstract Five sets of LFP/artificial graphite 18650 cells were assembled with the aim of limiting degradation to only lithium inventory loss. When this is the case, the well known “square root time model” for cell capacity, Q, as a function of initial capacity, Q_0, and time, t: Q=Q_0 (1-At^(1/2)) can be used to model capacity loss fairly well. Data collected at the same charge and discharge rate at various temperatures can be fitted to extract the parameter, A, as a function of temperature, T. In this work, plots of log⁡(A) versus 1/T were used to extract the activation energy, E_a, and frequency factor, γ, for A = γ exp-Ea/kT. At extreme temperatures, significant Fe dissolution from LFP and deposition on the graphite electrode occurs, which accelerates capacity loss. In these cases, a modified square root time model is used to extract A. Model parameters for capacity loss were extracted using three different methods, compared, and used to make lifetime predictions as a function of temperature.

Authors

Institutions

Publication Details

Journal
Journal of The Electrochemical Society
Published
2026-10-27
DOI
https://doi.org/10.1149/1945-7111/aeba27
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LFP/Graphite 18650 Cells Designed to Operate from 20 to 100oC for Studies of Degradation Mechanisms: Part 2 – Arrhenius Parameter Extraction and Lifetime Modelling

Claire Floras, Jeff R. Dahn, Sasha Martin Maher
2 links
Journal of The Electrochemical Society
Advanced Battery Technologies Research
article

LFP/Graphite 18650 Cells Designed to Operate from 20 to 100oC for Studies of Degradation Mechanisms: Part 2 – Arrhenius Parameter Extraction and Lifetime Modelling

Claire Floras, Jeff R. Dahn, Sasha Martin Maher
article en

Abstract

Abstract Five sets of LFP/artificial graphite 18650 cells were assembled with the aim of limiting degradation to only lithium inventory loss. When this is the case, the well known “square root time model” for cell capacity, Q, as a function of initial capacity, Q_0, and time, t: Q=Q_0 (1-At^(1/2)) can be used to model capacity loss fairly well. Data collected at the same charge and discharge rate at various temperatures can be fitted to extract the parameter, A, as a function of temperature, T. In this work, plots of log⁡(A) versus 1/T were used to extract the activation energy, E_a, and frequency factor, γ, for A = γ exp-Ea/kT. At extreme temperatures, significant Fe dissolution from LFP and deposition on the graphite electrode occurs, which accelerates capacity loss. In these cases, a modified square root time model is used to extract A. Model parameters for capacity loss were extracted using three different methods, compared, and used to make lifetime predictions as a function of temperature.

Journal of The Electrochemical Society
Dalhousie University (CA)
Affordable and clean energy
Openalex Percentile: Top 23%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon