A Study of a Phase Compensation Method Based on Generalized Transfer Functions

In the field of digital holographic microscopy (DHM), the microscope objective and the optical path of the system invariably introduce additional phase distortions. These distortions obscure the true phase information of the sample, thus compromising the accuracy of quantitative measurements. To address this issue, this paper proposes an accurate phase compensation method based on the generalized transfer function. By integrating the theory of image-plane diffraction-limited coherent imaging, our method precisely extracts the generalized transfer function of the imaging system through a single holographic recording of the “object-free field” and numerical reconstruction of the ideal wavefront, thereby achieving deterministic elimination of the wavefront aberrations to be measured. The experimental results demonstrate that the proposed method achieves significantly higher accuracy in three-dimensional topography detection compared with the conventional double-exposure technique. The nominal relative deviations from the corresponding bright-field optical microscopy measurements for 50 µm silica microspheres, 20 µm polystyrene microspheres, and mouse red blood cells were reduced to 0.67%, 1.4%, and 1.7%, respectively; compared with the double-exposure technique, these deviations were reduced by 70.61%, 30%, and 43.3%, respectively. Requiring only a single sample hologram after a one-time object-free calibration for high-fidelity wavefield reconstruction, this method effectively circumvents complex iterative computations and residual higher-order aberrations, thereby providing an efficient approach for high-precision dynamic phase compensation in digital holographic microscopy. Consequently, it holds significant application potential in fields such as real-time monitoring of living cells and quantitative characterization of micro- and nanostructures.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2026-10-27
DOI
https://doi.org/10.3390/photonics13111014
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study of a Phase Compensation Method Based on Generalized Transfer Functions

Weinan Caiyang, Qinghe Song, Jingwei Huang, 梁茜媛 Liang Xiyuan et al.
2 links
Photonics
Digital Holography and Microscopy
article

A Study of a Phase Compensation Method Based on Generalized Transfer Functions

Weinan Caiyang, Qinghe Song, Jingwei Huang, 梁茜媛 Liang Xiyuan, Xuyang Guo, Siying Wang, Shike Jin, Zhenbo Zhang
article en

Abstract

In the field of digital holographic microscopy (DHM), the microscope objective and the optical path of the system invariably introduce additional phase distortions. These distortions obscure the true phase information of the sample, thus compromising the accuracy of quantitative measurements. To address this issue, this paper proposes an accurate phase compensation method based on the generalized transfer function. By integrating the theory of image-plane diffraction-limited coherent imaging, our method precisely extracts the generalized transfer function of the imaging system through a single holographic recording of the “object-free field” and numerical reconstruction of the ideal wavefront, thereby achieving deterministic elimination of the wavefront aberrations to be measured. The experimental results demonstrate that the proposed method achieves significantly higher accuracy in three-dimensional topography detection compared with the conventional double-exposure technique. The nominal relative deviations from the corresponding bright-field optical microscopy measurements for 50 µm silica microspheres, 20 µm polystyrene microspheres, and mouse red blood cells were reduced to 0.67%, 1.4%, and 1.7%, respectively; compared with the double-exposure technique, these deviations were reduced by 70.61%, 30%, and 43.3%, respectively. Requiring only a single sample hologram after a one-time object-free calibration for high-fidelity wavefield reconstruction, this method effectively circumvents complex iterative computations and residual higher-order aberrations, thereby providing an efficient approach for high-precision dynamic phase compensation in digital holographic microscopy. Consequently, it holds significant application potential in fields such as real-time monitoring of living cells and quantitative characterization of micro- and nanostructures.

PhotonicsVol. 13(11)
Kunming University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 20%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon